Large-capacity model for critical industrial installations: refineries, steel mills, chemical plants, municipal water supply and mining. Back pull-out construction per ASME B73.1.
Maximum flow
850 m³/h
Head
55–132 m w.c.
Absorbed power
90–420 HP
NPSH required
3–9 m
Maximum efficiency
82%
Envelope read from the official 1750 rpm curve PDF (chart-reading precision, ~±half a grid division). For design, confirm the values with the FB Bombas engineering data sheet.
Q × H hydraulic envelope of the FBCN 200-500 pump at 1750 rpm, per the official FB Bombas technical catalog (curve CC-0206.09), with ISO 9906 hydraulic guarantees. Reference plot for pre-sizing — confirm the operating point with FB Bombas engineering.
Hydraulic envelope — all impellers
Overlaid H × Q curves. Each color represents one impeller diameter.
| Flow · m³/h | 0.0 | 250.0 | 500.0 | 700.0 | 850.0 |
|---|---|---|---|---|---|
| Head H · m | 132.0 | 128.0 | 120.0 | 112.0 | 103.0 |
| Flow · m³/h | 0.0 | 250.0 | 500.0 | 680.0 | 800.0 |
|---|---|---|---|---|---|
| Head H · m | 120.0 | 116.0 | 108.0 | 98.0 | 90.0 |
| Flow · m³/h | 0.0 | 250.0 | 450.0 | 650.0 | 760.0 |
|---|---|---|---|---|---|
| Head H · m | 110.0 | 106.0 | 99.0 | 88.0 | 80.0 |
| Flow · m³/h | 0.0 | 250.0 | 450.0 | 620.0 | 730.0 |
|---|---|---|---|---|---|
| Head H · m | 100.0 | 96.0 | 89.0 | 79.0 | 70.0 |
| Flow · m³/h | 0.0 | 250.0 | 450.0 | 600.0 | 710.0 |
|---|---|---|---|---|---|
| Head H · m | 90.0 | 86.0 | 79.0 | 70.0 | 60.0 |
| Flow · m³/h | 0.0 | 200.0 | 400.0 | 550.0 | 680.0 |
|---|---|---|---|---|---|
| Head H · m | 82.0 | 79.0 | 72.0 | 64.0 | 55.0 |
Each pump ships with the impeller diameter calculated by FB engineering for the specific operating point — design flow and head.
| # | Impeller diameter | Impeller useful width |
|---|---|---|
| 1 | 504 mm | 32 mm |
| 2 | 480 mm | 32 mm |
| 3 | 460 mm | 32 mm |
| 4 | 440 mm | 32 mm |
| 5 | 420 mm | 32 mm |
| 6 | 400 mm | 32 mm |
Technical questions about the FBCN 200-500 centrifugal pump.
FBCN large-capacity models do not have individual physical dimensions published in the standard technical manual. Each project receives dimensional drawing, project-specific performance curve and material selection through direct consultation with FB Bombas engineering.