Large-capacity model for critical industrial installations: refineries, steel mills, chemical plants, municipal water supply and mining. Back pull-out construction per ASME B73.1.
Maximum flow
1,400 m³/h
Head
18–50 m w.c.
Absorbed power
90–172 HP
NPSH required
6–10 m
Maximum efficiency
84%
Q × H hydraulic envelope of the FBCN 250-315 pump at 1750 rpm, per the official FB Bombas technical catalog (curve CC-0207.09), with ISO 9906 hydraulic guarantees. Reference plot for pre-sizing — confirm the operating point with FB Bombas engineering.
Hydraulic envelope — all impellers
Overlaid H × Q curves. Each color represents one impeller diameter.
| Flow · m³/h | 0.0 | 400.0 | 800.0 | 1,150.0 | 1,400.0 |
|---|---|---|---|---|---|
| Head H · m | 50.0 | 46.0 | 39.0 | 31.0 | 25.0 |
| Flow · m³/h | 0.0 | 400.0 | 800.0 | 1,100.0 | 1,300.0 |
|---|---|---|---|---|---|
| Head H · m | 43.0 | 40.0 | 34.0 | 27.0 | 22.0 |
| Flow · m³/h | 0.0 | 400.0 | 750.0 | 1,050.0 | 1,250.0 |
|---|---|---|---|---|---|
| Head H · m | 39.0 | 36.0 | 31.0 | 24.0 | 19.0 |
| Flow · m³/h | 0.0 | 400.0 | 700.0 | 950.0 | 1,150.0 |
|---|---|---|---|---|---|
| Head H · m | 35.0 | 32.0 | 27.0 | 22.0 | 18.0 |
Each pump ships with the impeller diameter calculated by FB engineering for the specific operating point — design flow and head.
| # | Impeller diameter | Impeller useful width |
|---|---|---|
| 1 | 324 mm | 74 mm |
| 2 | 320 mm | 74 mm |
| 3 | 310 mm | 74 mm |
| 4 | 300 mm | 74 mm |
Technical questions about the FBCN 250-315 centrifugal pump.
FBCN large-capacity models do not have individual physical dimensions published in the standard technical manual. Each project receives dimensional drawing, project-specific performance curve and material selection through direct consultation with FB Bombas engineering.