Fluid
Step 01Conversion
Viscosity converter
The data sheet gives SSU: what is it in cSt and cP?
- Equation
ν = μ/ρ · SSU (ASTM D2161)- Range
- 0.1 to 100,000 cSt
Calculate NPSH, head loss and power, or convert viscosity. Choose a tool, enter your data and follow the result alongside the installation diagram.
Use the four calculators in Portuguese, English or Spanish. The examples below use the same calculations as the tools on their own pages.
Fluid
Step 01Conversion
The data sheet gives SSU: what is it in cSt and cP?
ν = μ/ρ · SSU (ASTM D2161)Line
Step 02Value and parts
How much head do the pipe, valves and fittings use up?
hf = f·(L/D)·V²/2gSuction
Step 03Verdict
Does the suction meet the NPSH the pump requires?
NPSHa = (P0 − Pv)/(ρ·g) + Z1 − hLDrive
Step 04Power
What power does the pump draw at the duty point and at the end of the curve?
P = ρ·g·Q·H/ηIn preparation, no page yet: system curve and duty point; pumps in series and in parallel.
Each sheet shows the equation, the ranges with their origin, an example with inputs and outputs, the limit of the calculation and when to take the case to FB Bombas engineering.
Fluid
Direct answer. The converter takes a value in cSt, cP or SSU to the other units. cP requires the density at the same temperature.
ν = μ/ρ
SSU = 4.6324·ν + (1 + 0.03264·ν)/(3,930.2 + 262.7·ν + 23.97·ν² + 1.646·ν³)·10⁵, at 100 °F (37.8 °C), by ASTM D2161.
| Quantity | Range |
|---|---|
| Viscosity | 0.1 to 100,000 cSt (limit of the calculation) |
| SSU | from 32 s (limit of the ASTM D2161 correlation) |
| Density | required only for cP |
Initial example of the calculator: 100 cSt and 900 kg/m³.
The data sheet does not give the viscosity at the pumping temperature, or the fluid changes viscosity along the line.
Line
Direct answer. The calculator adds pipe friction loss and local loss for up to 5 runs, on a suction or discharge line.
hf = f·(L/D)·V²/2g (Darcy-Weisbach). In laminar flow, f = 64/Re (Re up to 2,000); in turbulent flow, Colebrook-White; in the transition (2,000 to 4,000) the larger of the two applies, with a warning.
Local loss: hL = K·V²/2g, with K from the Darby 3-K method, the Hooper 2-K method (butterfly) or Crane TP-410 (entrance, exit and foot valve).
| Quantity | Range |
|---|---|
| Inside diameter | 5 to 1,000 mm |
| Length | 0 to 10,000 m |
| Roughness | 0 to 10 mm |
| DN | 1/2″ to 24″ |
| Catalog roughness | commercial steel 0.046 mm · galvanized 0.15 mm · cast iron 0.26 mm · asphalted cast iron 0.12 mm · drawn tubing 0.0015 mm; PVC and plastic are treated as smooth pipe |
Initial example of the calculator: discharge line with water at 40 °C, 30 m³/h, three runs of DN 3″ steel (77.9 mm) of 15, 10 and 15 m. A 90° bend in the first; a gate valve and a check valve in the second; a bend and an exit into a reservoir in the third.
The fitting is not on the list (it enters as other, with K entered), the line has more than 5 distinct runs, or the regime is in the transition.
Suction
Direct answer. The calculator computes the NPSHa of the installation and, with the NPSHr from the manufacturer curve, reports one of three states: cavitation, insufficient margin or meets the screening.
NPSHa = (P0 − Pv)/(ρ·g) + Z1 − hL, with Z1 negative in suction lift.
The FB Bombas screening reference is the larger of 1.2·NPSHr and NPSHr + 1 m. Below the NPSHr: cavitation. Between the NPSHr and the reference: insufficient margin. From the reference upward: meets the screening.
For a gear pump, NPIPA = total inlet pressure − Pv.
| Quantity | Range |
|---|---|
| Water | 0.01 to 200 °C (IAPWS SR1-86) |
| Altitude | 0 to 5,000 m (ITU-R P.835) |
| Barometer | 50 to 110 kPa |
| NPSHr | 0.1 to 50 m |
| Flow | greater than zero |
Initial example of the calculator: water at 40 °C, 300 m altitude, open tank, suction lift of 3.00 m, 30 m³/h in 6.00 m of DN 3″ steel with a foot valve and a 90° bend, NPSHr of 4.80 m.
The result is insufficient margin or cavitation, the NPSHr is not on the curve at the working speed, the liquid vapor pressure is unknown, or a gear pump starts cold with viscous oil.
Drive
Direct answer. The calculator gives the hydraulic and shaft power at the duty point and, for the FBE, FBCN and FBOT series, the reserve from the manual table.
Hydraulic P = ρ·g·Q·H; shaft P = hydraulic P/η. For a gear pump, P = Q·Δp/η, which does not depend on density. 1 cv = 735.499 W, with g₀ = 9.80665 m/s².
FBE reserve (MTEC-01/01, p.4): up to 2 cv, 50 %; 3 to 5 cv, 30 %; 6 to 10 cv, 25 %; 11 to 25 cv, 15 %; above 25 cv, 10 %. FBCN (MTEC-03/00, p.7, Table 2): up to 20 cv, about 15 %; above, about 10 %. FBOT: MTEC-16/00, p.5.
| Quantity | Range |
|---|---|
| Efficiency | 5 to 95 % |
| Water | 0.01 to 200 °C |
| Density | 500 to 2,000 kg/m³ |
Initial example of the calculator: water at 20 °C (998.16 kg/m³), 50 m³/h, 40 m and efficiency of 70 %.
The power falls in a gap of the reserve table (for example 2.3 cv on the FBE; FBCN and FBOT up to 2 cv), or the starting, speed or fluid differ from the calculated point.
The order below follows the path of the data: from the liquid to the power.
Bring the value from the liquid data sheet to cSt, at the pumping temperature. It is the viscosity the NPSH and head loss calculators ask for when the liquid is not water.
Enter flow, runs and fittings. With the elevation change Δz or the pressure difference Δp between the ends, the calculator also shows the head of the run, including the loss.
Compare the NPSHa with the NPSHr from the manufacturer curve, at the same speed. The screening reference does not replace the pump curve.
Use the flow and head of the duty point and the efficiency read on the curve. With the FBE, FBCN or FBOT series, the reserve comes from the manual table; the commercial motor rating stays with FB Bombas engineering.

Head loss and NPSH use the same example line (30 m³/h, DN 3″, water at 40 °C): velocity of 1.748 m/s and Re of 207,040 in both.
Screening calculation with the assumptions shown. FB Bombas engineering confirms the selection.
Each quantity, the source the calculation engine uses and the tools that depend on it.
| Quantity or method | Source | Tool |
|---|---|---|
| Water vapor pressure and density | IAPWS SR1-86 | NPSH, head loss, power |
| Water viscosity | IAPWS R12-08 | NPSH, head loss |
| Atmospheric pressure from altitude | ITU-R P.835 | NPSH |
| Pipe friction | Darcy-Weisbach and Colebrook-White | Head loss, NPSH |
| Fitting K | Darby 3-K method, Hooper 2-K method and Crane TP-410 | Head loss, NPSH |
| Roughness | Catalog values; commercial steel 0.046 mm | Head loss, NPSH |
| SSU and cSt | ASTM D2161 | Viscosity |
| Power | P = ρ·g·Q·H/η, with g₀ = 9.80665 m/s² | Power |
| Motor reserve | Manuals FBE MTEC-01/01, FBCN MTEC-03/00 and FBOT MTEC-16/00 | Power |
| NPSH reference | FB Bombas screening criterion, not a Hydraulic Institute margin | NPSH |
Pressure in kgf/cm² (1 kgf/cm² = 98,066.5 Pa), with kPa and mmHg on the barometer inputs. Decimal comma in Portuguese and Spanish, decimal point in English. Screening calculation with the assumptions shown on screen. None of the four chooses the pump model or replaces the manufacturer curve.
Direct answers, taken from what each calculator does. Each answer starts with what you need to know.
Viscosity, head loss, NPSH and power: each step hands the next one its data. The viscosity in cSt feeds head loss and NPSH when the liquid is not water; the line loss enters the NPSH and the head of the duty point; power closes the calculation. See the order of use above.
None of them chooses the model alone. Together they give the line loss, the suction condition and the power at the duty point. FB Bombas engineering confirms the selection with the model curve: send the result and the installation data by WhatsApp or through the quote.
It compares the NPSHa with the NPSHr and with the screening reference, the larger of 1.2·NPSHr and NPSHr + 1 m. Below the NPSHr: cavitation. Between the NPSHr and the reference: insufficient margin. From the reference upward: meets the screening. The NPSH data sheet above has an example with the numbers.
Yes, in another mode. It shows the NPIPA, the pressure available above the vapor pressure, and the absolute and gauge pressure at the inlet. Cold start is optional and requires the cold viscosity. FB Bombas engineering compares the result with the pump requirement.
Darcy-Weisbach, with a laminar or Colebrook-White friction factor, using the larger in the transition. Fittings use the Darby 3-K method, the Hooper 2-K method or Crane TP-410; you can also enter K. The line has up to 5 runs, with water or another liquid.
By P = ρ·g·Q·H/η at the duty point; for a gear pump, by P = Q·Δp/η. The efficiency comes from the model curve, between 5 and 95 %. With FBE, FBCN or FBOT, the reserve comes from the series manual table; the commercial motor rating stays with FB Bombas engineering.
In the viscosity converter, enter the value in the unit of the data sheet. SSU is Saybolt Universal at 100 °F, converted by ASTM D2161, and holds from 32 s upward. For cP, the density at the same temperature is required.
No. It is a screening calculation with the assumptions shown on screen. FB Bombas engineering confirms the selection.