Pump engineering tools Start with your process data.

Calculate NPSH, head loss and power, or convert viscosity. Choose a tool, enter your data and follow the result alongside the installation diagram.

Calculate with your installation data.

Use the four calculators in Portuguese, English or Spanish. The examples below use the same calculations as the tools on their own pages.

  1. Line

    Step 02Value and parts

    Head loss

    How much head do the pipe, valves and fittings use up?

    Run 10.62 mRun 20.69 mRun 30.78 mfriction 1.54 mfittings 0.55 mtotal 2.085 m
    Initial example of the calculator: discharge line with water at 40 °C, 30 m³/h, three runs of DN 3″ steel of 15, 10 and 15 m.
    Equation
    hf = f·(L/D)·V²/2g
    Range
    inside diameter 5 to 1,000 mm
  2. Suction

    Step 03Verdict

    Available NPSH and inlet pressure

    Does the suction meet the NPSH the pump requires?

    NPSHa 4.88 mNPSHr 4.80reference 5.80cavitationinsufficient marginmeets
    Initial example of the calculator: water at 40 °C, 300 m altitude, 3.00 m suction lift, 30 m³/h and an NPSHr of 4.80 m.
    Equation
    NPSHa = (P0 − Pv)/(ρ·g) + Z1 − hL
    Range
    water 0.01 to 200 °C · altitude 0 to 5,000 m
  3. Drive

    Step 04Power

    Shaft power and motor reserve

    What power does the pump draw at the duty point and at the end of the curve?

    hydraulic5.44 kWshaft7.77 kWwith reserve8.93 kW10.56 cv · 12.15 cv
    Initial example of the calculator: water at 20 °C, 50 m³/h, 40 m and efficiency of 70 %; FBCN series reserve.
    Equation
    P = ρ·g·Q·H/η
    Range
    efficiency 5 to 95 %

In preparation, no page yet: system curve and duty point; pumps in series and in parallel.

How each calculation works, where it holds and what it leaves out.

Each sheet shows the equation, the ranges with their origin, an example with inputs and outputs, the limit of the calculation and when to take the case to FB Bombas engineering.

Fluid

Viscosity converter: equation, range and example

Direct answer. The converter takes a value in cSt, cP or SSU to the other units. cP requires the density at the same temperature.

Equation

ν = μ/ρ

SSU = 4.6324·ν + (1 + 0.03264·ν)/(3,930.2 + 262.7·ν + 23.97·ν² + 1.646·ν³)·10⁵, at 100 °F (37.8 °C), by ASTM D2161.

See the ranges and origin, example and limits
Ranges and origin
QuantityRange
Viscosity0.1 to 100,000 cSt (limit of the calculation)
SSUfrom 32 s (limit of the ASTM D2161 correlation)
Densityrequired only for cP

Example

Initial example of the calculator: 100 cSt and 900 kg/m³.

  • 90 cP, 0.09 Pa·s and 463.5 SSU.
  • Inverse: 1,000 SSU equal 215.9 cSt.

What it does not do

  • It does not choose the pump model.
  • SSU refers to 100 °F, and viscosity changes with temperature: use the value at the pumping temperature.
  • ASTM keeps the practice for converting old SSU data and recommends reporting in mm²/s (the same as cSt).

Call FB Bombas engineering when

The data sheet does not give the viscosity at the pumping temperature, or the fluid changes viscosity along the line.

Line

Head loss: equation, range and example

Direct answer. The calculator adds pipe friction loss and local loss for up to 5 runs, on a suction or discharge line.

Equation

hf = f·(L/D)·V²/2g (Darcy-Weisbach). In laminar flow, f = 64/Re (Re up to 2,000); in turbulent flow, Colebrook-White; in the transition (2,000 to 4,000) the larger of the two applies, with a warning.

Local loss: hL = K·V²/2g, with K from the Darby 3-K method, the Hooper 2-K method (butterfly) or Crane TP-410 (entrance, exit and foot valve).

See the ranges and origin, example and limits
Ranges and origin
QuantityRange
Inside diameter5 to 1,000 mm
Length0 to 10,000 m
Roughness0 to 10 mm
DN1/2″ to 24″
Catalog roughnesscommercial steel 0.046 mm · galvanized 0.15 mm · cast iron 0.26 mm · asphalted cast iron 0.12 mm · drawn tubing 0.0015 mm; PVC and plastic are treated as smooth pipe

Example

Initial example of the calculator: discharge line with water at 40 °C, 30 m³/h, three runs of DN 3″ steel (77.9 mm) of 15, 10 and 15 m. A 90° bend in the first; a gate valve and a check valve in the second; a bend and an exit into a reservoir in the third.

  • Velocity 1.748 m/s, Re 207,040, f 0.01921, turbulent.
  • Losses of 0.622 m, 0.686 m and 0.778 m: a total of 2.085 m.
  • Friction accounts for 1.538 m (74 %) and the fittings for 0.547 m (26 %).

What it does not do

  • It uses one kinematic viscosity per line, so non-Newtonian behavior is not covered.
  • A turbulent-regime K applied to laminar flow can underestimate the loss.
  • Used pipe has a higher roughness than the catalog value.

Call FB Bombas engineering when

The fitting is not on the list (it enters as other, with K entered), the line has more than 5 distinct runs, or the regime is in the transition.

Suction

NPSH: equation, range and example

Direct answer. The calculator computes the NPSHa of the installation and, with the NPSHr from the manufacturer curve, reports one of three states: cavitation, insufficient margin or meets the screening.

Equation

NPSHa = (P0 − Pv)/(ρ·g) + Z1 − hL, with Z1 negative in suction lift.

The FB Bombas screening reference is the larger of 1.2·NPSHr and NPSHr + 1 m. Below the NPSHr: cavitation. Between the NPSHr and the reference: insufficient margin. From the reference upward: meets the screening.

For a gear pump, NPIPA = total inlet pressure − Pv.

See the ranges and origin, example and limits
Ranges and origin
QuantityRange
Water0.01 to 200 °C (IAPWS SR1-86)
Altitude0 to 5,000 m (ITU-R P.835)
Barometer50 to 110 kPa
NPSHr0.1 to 50 m
Flowgreater than zero

Example

Initial example of the calculator: water at 40 °C, 300 m altitude, open tank, suction lift of 3.00 m, 30 m³/h in 6.00 m of DN 3″ steel with a foot valve and a 90° bend, NPSHr of 4.80 m.

  • Patm 97.77 kPa, Pv 7.385 kPa, density 992.17 kg/m³.
  • Suction loss of 1.409 m, of which 1.134 m comes from the foot valve (K = 7.273).
  • NPSHa of 4.880 m: a margin of 0.080 m over the NPSHr, reference of 5.80 m. Result: insufficient margin.

What it does not do

  • The result holds for the minimum tank level and the highest operating flow.
  • New pipe gives the minimum loss.
  • It does not replace the pump curve or the test.
  • For a gear pump there is no NPSHr verdict: engineering compares the NPIPA with the pump requirement.

Call FB Bombas engineering when

The result is insufficient margin or cavitation, the NPSHr is not on the curve at the working speed, the liquid vapor pressure is unknown, or a gear pump starts cold with viscous oil.

Drive

Shaft power and motor reserve: equation, range and example

Direct answer. The calculator gives the hydraulic and shaft power at the duty point and, for the FBE, FBCN and FBOT series, the reserve from the manual table.

Equation

Hydraulic P = ρ·g·Q·H; shaft P = hydraulic P/η. For a gear pump, P = Q·Δp/η, which does not depend on density. 1 cv = 735.499 W, with g₀ = 9.80665 m/s².

FBE reserve (MTEC-01/01, p.4): up to 2 cv, 50 %; 3 to 5 cv, 30 %; 6 to 10 cv, 25 %; 11 to 25 cv, 15 %; above 25 cv, 10 %. FBCN (MTEC-03/00, p.7, Table 2): up to 20 cv, about 15 %; above, about 10 %. FBOT: MTEC-16/00, p.5.

See the ranges and origin, example and limits
Ranges and origin
QuantityRange
Efficiency5 to 95 %
Water0.01 to 200 °C
Density500 to 2,000 kg/m³

Example

Initial example of the calculator: water at 20 °C (998.16 kg/m³), 50 m³/h, 40 m and efficiency of 70 %.

  • Hydraulic power 5.438 kW; shaft power 7.769 kW (10.56 cv).
  • With the FBCN series, range up to 20 cv, reserve of 15 %: 8.934 kW (12.15 cv).

What it does not do

  • The efficiency comes from the model curve at the duty point, and the end of the curve is typed by you.
  • The commercial motor rating stays with FB Bombas engineering.

Call FB Bombas engineering when

The power falls in a gap of the reserve table (for example 2.3 cv on the FBE; FBCN and FBOT up to 2 cv), or the starting, speed or fluid differ from the calculated point.

How to use the results in selection.

The order below follows the path of the data: from the liquid to the power.

  1. Convert the viscosity

    Bring the value from the liquid data sheet to cSt, at the pumping temperature. It is the viscosity the NPSH and head loss calculators ask for when the liquid is not water.

    Hands over
    ν in cSt, at the pumping temperature
    Feeds
    Head loss and NPSH, when the liquid is not water
  2. Calculate the line loss

    Enter flow, runs and fittings. With the elevation change Δz or the pressure difference Δp between the ends, the calculator also shows the head of the run, including the loss.

    Hands over
    Suction line loss and head of the duty point, with the loss
    Feeds
    NPSH and power
  3. Check the suction against the curve

    Compare the NPSHa with the NPSHr from the manufacturer curve, at the same speed. The screening reference does not replace the pump curve.

    Hands over
    Margin against the NPSHr on the manufacturer curve
    Feeds
    Model choice
  4. Estimate the power

    Use the flow and head of the duty point and the efficiency read on the curve. With the FBE, FBCN or FBOT series, the reserve comes from the manual table; the commercial motor rating stays with FB Bombas engineering.

    Hands over
    Shaft power and motor reserve
    Feeds
    Motor confirmation by FB Bombas engineering
The FB Bombas stand at Paving Expo 2026, seen head-on, with external gear pumps on the counter
The FB Bombas stand at Paving Expo 2026.

Head loss and NPSH use the same example line (30 m³/h, DN 3″, water at 40 °C): velocity of 1.748 m/s and Re of 207,040 in both.

Screening calculation with the assumptions shown. FB Bombas engineering confirms the selection.

Where the equations and data come from.

Each quantity, the source the calculation engine uses and the tools that depend on it.

Sources of the calculators' equations and data
Quantity or methodSourceTool
Water vapor pressure and densityIAPWS SR1-86NPSH, head loss, power
Water viscosityIAPWS R12-08NPSH, head loss
Atmospheric pressure from altitudeITU-R P.835NPSH
Pipe frictionDarcy-Weisbach and Colebrook-WhiteHead loss, NPSH
Fitting KDarby 3-K method, Hooper 2-K method and Crane TP-410Head loss, NPSH
RoughnessCatalog values; commercial steel 0.046 mmHead loss, NPSH
SSU and cStASTM D2161Viscosity
PowerP = ρ·g·Q·H/η, with g₀ = 9.80665 m/s²Power
Motor reserveManuals FBE MTEC-01/01, FBCN MTEC-03/00 and FBOT MTEC-16/00Power
NPSH referenceFB Bombas screening criterion, not a Hydraulic Institute marginNPSH

Pressure in kgf/cm² (1 kgf/cm² = 98,066.5 Pa), with kPa and mmHg on the barometer inputs. Decimal comma in Portuguese and Spanish, decimal point in English. Screening calculation with the assumptions shown on screen. None of the four chooses the pump model or replaces the manufacturer curve.

Engineer questions.

Direct answers, taken from what each calculator does. Each answer starts with what you need to know.

In what order should I use the calculators?

Viscosity, head loss, NPSH and power: each step hands the next one its data. The viscosity in cSt feeds head loss and NPSH when the liquid is not water; the line loss enters the NPSH and the head of the duty point; power closes the calculation. See the order of use above.

Which tool do I use to size a pump?

None of them chooses the model alone. Together they give the line loss, the suction condition and the power at the duty point. FB Bombas engineering confirms the selection with the model curve: send the result and the installation data by WhatsApp or through the quote.

How does the NPSH calculator decide between meets, insufficient margin and cavitation?

It compares the NPSHa with the NPSHr and with the screening reference, the larger of 1.2·NPSHr and NPSHr + 1 m. Below the NPSHr: cavitation. Between the NPSHr and the reference: insufficient margin. From the reference upward: meets the screening. The NPSH data sheet above has an example with the numbers.

Does the NPSH calculator work for a gear pump?

Yes, in another mode. It shows the NPIPA, the pressure available above the vapor pressure, and the absolute and gauge pressure at the inlet. Cold start is optional and requires the cold viscosity. FB Bombas engineering compares the result with the pump requirement.

What method does the head loss calculator use?

Darcy-Weisbach, with a laminar or Colebrook-White friction factor, using the larger in the transition. Fittings use the Darby 3-K method, the Hooper 2-K method or Crane TP-410; you can also enter K. The line has up to 5 runs, with water or another liquid.

How are pump power and motor reserve calculated?

By P = ρ·g·Q·H/η at the duty point; for a gear pump, by P = Q·Δp/η. The efficiency comes from the model curve, between 5 and 95 %. With FBE, FBCN or FBOT, the reserve comes from the series manual table; the commercial motor rating stays with FB Bombas engineering.

How do I convert SSU to cSt and cP?

In the viscosity converter, enter the value in the unit of the data sheet. SSU is Saybolt Universal at 100 °F, converted by ASTM D2161, and holds from 32 s upward. For cP, the density at the same temperature is required.

Do the calculator results define the pump?

No. It is a screening calculation with the assumptions shown on screen. FB Bombas engineering confirms the selection.

Discuss your application with FB Bombas