Skip to main content

Multistage pump: how it works, when to use it and how to choose

A multistage pump is a centrifugal pump with several impellers on the same shaft, one per stage, which together deliver more head than a single impeller. The FBME from FB Bombas is horizontal, runs from 3″ to 6″ and reaches 300 m of head and 400 m³/h, general limits that do not occur together.

FBME multistage pump from the FB Bombas collection
FBME series — photograph from the FB Bombas collection.
FBME multistage pump from the FB Bombas collection
FBME series — photograph from the FB Bombas collection.

Updated

How does a multistage pump add head?

A multistage pump has several impellers on one shaft, one per stage. The same flow passes through every stage. Each stage adds pressure and head, as the Hydraulic Institute explains, allowing the pump to serve systems requiring high head.

What FB Bombas documents show on the FBME

  • One casing, one impeller and one diffuser per stage

    In the FBME Series technical manual, the impellers are radial, closed and single-suction, mounted in diffusers (p. 5). The stage casings sit between the suction and discharge casings, joined by external tie rods (p. 1), and the parts list carries one impeller per stage (p. 7).

  • The assembly head is the sum of the stages

    The curve sheet for the FBME 6″ at 1,750 rpm (curve CC-0242.10) notes "FBME 6/2 (2 stages): 300 m³/h x 90 mca (45 per stage)": 45 m in each stage, 90 m in the assembly, at the same flow.

  • More stages, a higher head range

    In the quick selection chart of the technical manual (p. 3), each size appears in models of 1, 2, 3 stages or more (3/1, 3/2, 3/3), and each added stage moves the model range to a higher head, within the same flow range. The scale goes up to 300 m.

Horizontal or vertical multistage pump?

The FBME is horizontal: the shaft lies horizontal and the stage casings are assembled axially, one after another, between the suction and discharge casings. The suction flange sits in the horizontal direction, on the coupled side; the discharge flange sits in the vertical direction, on the non-coupled side. The series documents describe only this configuration.

  • Electric motor drive, with a standard FB Bombas flexible coupling or one from another manufacturer, and a coupling guard (technical manual, p. 5).
  • Welded structural steel baseplate for the assembly (technical manual, p. 5).
  • Rolling-element bearings, grease or oil lubricated, with the shaft sealed by packing or a mechanical seal (technical manual, p. 5).
  • For a configuration other than horizontal, consult FB Bombas engineering: the FBME manuals do not describe one.

When should you use a multistage pump?

Use one when the required total head is high for a single-stage centrifugal pump. In FB Bombas manuals, the single-stage FBCN reaches 135 m and the multistage FBME reaches 300 m. These are general limits of each series, not simultaneous: flow, head, speed and temperature depend on the curve and on the duty point.

FBME (multistage) and FBCN (single-stage): general limits of each series
ItemFBME, multistageFBCN, single-stage
SizesDN 80 to 150, from 3″ to 6″DN 25 to 300 mm
FlowUp to 400 m³/hUp to 2,200 m³/h
Total headUp to 300 mUp to 135 m
TemperatureUp to 140 °C, depending on sealingUp to 260 °C
SpeedUp to 3,500 rpmUp to 3,500 rpm

Source: FBME (MTEC-08/01) and FBCN (MTEC-03/00) technical manuals, p. 1 of each. The FBCN covers more flow and temperature; the FBME covers more head. Both manuals indicate clean or turbid liquids; with suspended solids, the FBME manual says to consult FB Bombas before selection.

Industries that the FBME technical manual lists, on p. 1:

  • Chemical
  • Petrochemical
  • Paper
  • Pulp
  • Steel
  • Mining
  • Food
  • Textile
  • Pharmaceutical
  • Sanitation

For the single-stage pump principle, see the guide to the centrifugal pump.

How do you read the name and curve of the FBME pump?

The name gives the size and the stages: in the FBME 4/3, the 4 is the nominal discharge diameter, in inches, and the 3 is the number of stages. The curve gives, for each impeller diameter, the head, efficiency, NPSH and power as a function of flow. Read the duty point on it, not the series maxima.

FBME 4/3 designation, part by part
PartMeaning in the manualIn the FBME 4/3
MEModel: multistage centrifugal, after the brandFBME Series
First numberNominal discharge diameter, in inches4″, with DN 100 discharge and DN 125 suction (p. 12)
Second numberNumber of stages3 stages

Original FBME curve sheets, in PDF (60 Hz, per the technical manual, p. 3):

The sheets use different conventions: confirm the power unit and whether the head refers to one stage or to the assembly before sizing. The HB-6-2 is a specific 2-stage configuration sheet; confirm that it applies to the proposed assembly.

What should you check about NPSH on a multistage pump?

The FBME curve sheet carries the NPSH graph together with head, efficiency and power. The installation manual treats a lack of NPSH as a suction problem: it says to check the NPSH, change the suction height if necessary and lower it when the NPSH is insufficient.

Compare the NPSH on the curve, at your duty point, with what the installation provides.

  • On the curve, read the NPSH at the duty-point flow, on the chosen impeller diameter. Check the unit on each sheet: the 4″ and HB-6-2 sheets state meters.
  • In the installation manual (p. 21), "suction height too high" calls for checking the NPSH and changing the suction height; "insufficient NPSH" calls for lowering the suction height.
  • According to the Hydraulic Institute, the available NPSH must have a margin over the required one. The NPSH calculator on this site does the calculation for your installation.

Open the NPSH calculator.

Packing, cooled packing or mechanical seal?

On the FBME, the shaft is sealed by packing or a mechanical seal, and the liquid temperature decides. Uncooled packing runs from −10 to +105 °C; with chamber cooling, from +105 to +140 °C. A single mechanical seal without cooling runs up to about 105 °C, depending on the seal manufacturer.

FBME shaft sealing by temperature and suction condition
SealingTemperatureCondition
Uncooled packing−10 to +105 °CSuction pressure below or above 1 bar, with a pressure-relief line and sealing with circulation from the discharge casing to the suction casing.
Cooled packing+105 to +140 °CSuction pressure above 1 bar. The chamber cooling line is provided by the customer installation: inlet water up to 40 °C, outlet up to 60 °C, up to 6 bar, 150 l/h per pump on the 3″ and 4″ and 170 l/h on the 5″ and 6″.
Single mechanical sealUp to about 105 °C, without cooling, depending on the seal manufacturerBalanced or unbalanced; consider the suction pressure when selecting the seal. Table 1 of the manual gives a +140 °C maximum and refers to the seal manufacturer recommendation.

Source: FBME technical manual, Table 1 (p. 4) and Figure 3 (p. 10). For suspended solids, the manual says to consult FB Bombas.

What does the manual recommend for the piping of a multistage pump?

The FBME Series installation manual recommends watertight piping that puts no load on the pump casing, and a reference velocity of 1 to 2 m/s to size the suction flange. On the suction side, an eccentric reducer; on the discharge side, a concentric reducer and a control valve. These are the manufacturer recommendations for this series (p. 9 and 10).

Suction piping

  • Velocity between 1 and 2 m/s as the reference for the flange diameter; the nominal flange diameter does not set the pipe diameter.
  • Eccentric reducer, cone down, to prevent air pockets.
  • With a foot valve, a flow area 1.5 times the pipe area; for the strainer, 3 to 4 times.
  • Hat-type strainer on the suction, after thorough flushing of piping and tank, to protect the pump.
  • Positive suction: a shut-off valve on each pump, fully open in operation, and a slight upward slope from pump to tank; negative suction: a slight downward slope, so air pockets do not form.
  • For the suction, the manual refers to the Hydraulic Institute recommendations.

Discharge piping

  • Concentric reducer when the pipe diameter differs from the pump flange.
  • Control valve to regulate flow without overloading the motor.
  • If needed, a check valve between the pump and the control valve.
  • A water hammer control device, if overpressure makes the fluid flow back.
  • Air release valves where air is purged, and a safety valve or relief devices, if needed.
  • Metallic joints to absorb the system reaction loads.

Across the whole line: straight, short pipes, long-radius bends, expansion joints when the fluid temperature varies, and piping connected only after the concrete has cured. After tightening the piping bolts, check the coupling alignment. To estimate piping losses, use the head loss calculator.

Which multistage pump does FB Bombas make?

FB Bombas makes the FBME Series: a horizontal multistage centrifugal pump from 3″ to 6″ (DN 80 to 150), for clean or turbid liquids, with curves at 1,750 rpm (3″ to 6″) and at 3,500 rpm (3″). This page explains the pump type; the series page carries the sizes, curves, sealing and documents.

Frequently asked questions

How many stages can the FBME multistage pump have?

It depends on size and speed. Per Table 1 of the technical manual (p. 4), without a cooling chamber, the maximum up to 1,800 rpm is 14 stages on the 3″, 10 on the 4″, 8 on the 5″ and 4 on the 6″.

Up to 3,500 rpm, 4 stages on the 3″ and 3 on the 4″, and the 5″ and 6″ have no value at that speed. The number of stages for your case comes from the flow and head point, on the curve for the size and speed.

How do you start a multistage pump, and what is the minimum flow?

The FBME installation manual (p. 13) says to check the motor rotation direction with the pump uncoupled, so it does not run dry; the pump rotates clockwise, seen from the suction side (technical manual, p. 4).

Before starting, prime the pump and the suction line, fully open the suction valve and close the discharge valve; once the motor reaches rated speed, open the discharge valve slowly to the duty point. The stated minimum flow is 0.2 times the optimum flow (Q optimum), and the maximum follows the curve.

What are the maximum suction and discharge pressures of the FBME?

Table 1 of the technical manual (p. 4) gives a maximum suction pressure of 10 bar and a maximum discharge pressure, at zero flow, of 30 bar.

Flanges change with the pressure range and size: from ANSI B16.1 125#FF (cast iron) or B16.5 150#RF (steel) up to 16 bar, to 250#FF or 300#RF up to 30 bar, with a DIN EN 1092 option. These limits do not replace the total head of the selection.

Do the FBME curves apply to 50 Hz?

Not directly. The technical manual (p. 3) presents quick selection at 1,750 rpm and 3,500 rpm for 60 Hz, and the curve sheets carry a speed of 1,750 or 3,500 rpm. For a 50 Hz supply, state the frequency in your request: FB Bombas engineering confirms the duty point and the proposal, without extrapolating the 60 Hz curve.

Discuss your duty point with engineering

Send the liquid and temperature, the flow, the total head and the suction condition. FB Bombas engineering indicates the size, the number of stages, the sealing and the drive for the submitted duty point.

Selection depends on process conditions and confirmed data. The assessment and supply scope will be defined with the technical team.

Information for the assessment

  1. Liquid, temperature and suspended solids, if any
  2. Required flow and total head
  3. Suction condition: positive or negative, height and pressure
  4. Supply frequency (60 or 50 Hz) and operating regime
  5. For a replacement: the nameplate and photos of the installed pump

Keep in the technical cluster