Large-capacity model for critical industrial installations: refineries, steel mills, chemical plants, municipal water supply and mining. Back pull-out construction per ASME B73.1.
Maximum flow
1,000 m³/h
Head
15–50 m w.c.
Absorbed power
40–180 HP
NPSH required
3–7 m
Maximum efficiency
80%
Q × H hydraulic envelope of the FBCN FBCN 200-315 pump at 1750 rpm, extracted from the official FBCN Technical Manual (curve CC-0204.09) and bench-validated at FB Bombas test facility in Cabreúva–SP, Brazil.
Hydraulic envelope — all impellers
Overlaid H × Q curves. Each color represents one impeller diameter.
| Flow · m³/h | 200.0 | 400.0 | 600.0 | 800.0 | 900.0 |
|---|---|---|---|---|---|
| Head H · m | 47.0 | 45.0 | 41.0 | 33.0 | 26.0 |
| Flow · m³/h | 200.0 | 400.0 | 600.0 | 800.0 |
|---|---|---|---|---|
| Head H · m | 42.0 | 39.0 | 34.0 | 25.0 |
| Flow · m³/h | 200.0 | 400.0 | 600.0 | 800.0 |
|---|---|---|---|---|
| Head H · m | 37.0 | 33.0 | 27.0 | 17.0 |
| Flow · m³/h | 200.0 | 400.0 | 600.0 |
|---|---|---|---|
| Head H · m | 32.0 | 27.0 | 20.0 |
Each pump ships with the impeller diameter calculated by FB engineering for the specific operating point — design flow and head.
| # | Impeller diameter | Impeller useful width |
|---|---|---|
| 1 | 320 mm | 50 mm |
| 2 | 300 mm | 50 mm |
| 3 | 280 mm | 50 mm |
| 4 | 273 mm | 50 mm |
FBCN large-capacity models do not have individual physical dimensions published in the standard technical manual. Each project receives dimensional drawing, project-specific performance curve and material selection through direct consultation with FB Bombas engineering.