Large-capacity model for critical industrial installations: refineries, steel mills, chemical plants, municipal water supply and mining. Back pull-out construction per ASME B73.1.
Maximum flow
2,250 m³/h
Head
7–47 m w.c.
Absorbed power
80–175 HP
NPSH required
13–22 m
Maximum efficiency
85%
Q × H hydraulic envelope of the FBCN 300-340 pump at 1750 rpm, per the official FB Bombas technical catalog (curve CC-0211.09), with ISO 9906 hydraulic guarantees. Reference plot for pre-sizing — confirm the operating point with FB Bombas engineering.
Hydraulic envelope — all impellers
Overlaid H × Q curves. Each color represents one impeller diameter.
| Flow · m³/h | 0.0 | 600.0 | 1,200.0 | 1,800.0 | 2,250.0 |
|---|---|---|---|---|---|
| Head H · m | 47.0 | 42.0 | 33.0 | 22.0 | 11.0 |
| Flow · m³/h | 0.0 | 600.0 | 1,200.0 | 1,700.0 | 2,100.0 |
|---|---|---|---|---|---|
| Head H · m | 40.0 | 36.0 | 28.0 | 18.0 | 10.0 |
| Flow · m³/h | 0.0 | 600.0 | 1,150.0 | 1,600.0 | 2,000.0 |
|---|---|---|---|---|---|
| Head H · m | 36.0 | 32.0 | 25.0 | 16.0 | 9.0 |
| Flow · m³/h | 0.0 | 600.0 | 1,100.0 | 1,550.0 | 1,900.0 |
|---|---|---|---|---|---|
| Head H · m | 32.0 | 28.0 | 22.0 | 14.0 | 7.0 |
Each pump ships with the impeller diameter calculated by FB engineering for the specific operating point — design flow and head.
| # | Impeller diameter | Impeller useful width |
|---|---|---|
| 1 | 351 mm | 75 mm |
| 2 | 343 mm | 75 mm |
| 3 | 321 mm | 75 mm |
| 4 | 300 mm | 75 mm |
| 5 | 289 mm | 75 mm |
| 6 | 265 mm | 75 mm |
| 7 | 241 mm | 75 mm |
| 8 | 213 mm | 75 mm |
Technical questions about the FBCN 300-340 centrifugal pump.
FBCN large-capacity models do not have individual physical dimensions published in the standard technical manual. Each project receives dimensional drawing, project-specific performance curve and material selection through direct consultation with FB Bombas engineering.