Technical Dimensions
Dimensions in millimeters per FBEI Technical Manual — FB Bombas
| Dimension | Value (mm) |
|---|---|
| A | 1" |
| B | 102 |
| C | 70 |
| D | 41 |
| E | 33 |
| F | 102 |
| G | 62 |
| H | 9 |
| J | 24 |
| K | 1 |
| L | 102 |
| M | 17 |
| N | 29 |
| O | 8 |
| P | 16 |
| Q | 186 |
| S | 29 |
| T | 12.70 |
| U | 17 |
| W | 67 |
| X | 10 |
Source: Official FBEI Technical Manual (Fig. 11) — all dimensions in millimeters. Missing fields do not apply to this configuration.
Construction Features
Per official manufacturer documentation
Operating Principle
Positive displacement — gear within a gear (rotor + idler + crescent)
Sealing Options
- Mechanical seal (single or cartridge)
- Braided packing with adjustable gland
Heating Jacket (optional)
Steam must not exceed 185°C and/or 10 bar. Thermal fluid limited to 232°C and/or 10 bar (technical manual).
Installation Requirements
Spare Parts (2 years)
- Internal gear
- Pin
- Support and internal gear bushings
- Sealing kit (packing or mechanical seal + bearing)
When to choose the compact configuration
The compact configuration prioritizes space and weight savings — ideal for skids, portable systems and installations where physical space is restricted. Requires external overpressure protection (in-line valve, pressure switch or torque limiter), per the technical manual. Great for applications where reduced dimensions are a priority and the line already has its own protection.
Frequently Asked Questions
Model-specific technical answers based on the official manual
Application-Specific Performance
Flow rate, pressure, speed and power are sized for each specific application (fluid, viscosity, temperature, required pressure and available NPSH). Request free technical sizing — response within 48 business hours.
All dimensions and construction information were extracted from the official FB Bombas FBEI Technical Manual. For customized performance specifications, consult the Technical Assistance Department.