Internal gear pump — nominal size 1" — compact configuration.
Dimensions in millimeters per FBEI Technical Manual — FB Bombas
| Dimension | Value (mm) |
|---|---|
| A | 1" |
| B | 102 |
| C | 70 |
| D | 41 |
| E | 33 |
| F | 102 |
| G | 62 |
| H | 9 |
| J | 24 |
| K | 1 |
| L | 102 |
| M | 17 |
| N | 29 |
| O | 8 |
| P | 16 |
| Q | 186 |
| S | 29 |
| T | 12.70 |
| U | 17 |
| W | 67 |
| X | 10 |
Source: Official FBEI Technical Manual (Fig. 11) — all dimensions in millimeters. Missing fields do not apply to this configuration.
Per official manufacturer documentation
Positive displacement — gear within a gear (rotor + idler + crescent)
Steam must not exceed 185°C and/or 10 bar. Thermal fluid limited to 232°C and/or 10 bar (technical manual).
The compact configuration prioritizes space and weight savings — ideal for skids, portable systems and installations where physical space is restricted. Requires external overpressure protection (in-line valve, pressure switch or torque limiter), per the technical manual. Great for applications where reduced dimensions are a priority and the line already has its own protection.
Model-specific technical answers based on the official manual
Flow rate, pressure, speed and power are sized for each specific application (fluid, viscosity, temperature, required pressure and available NPSH). Request free technical sizing — technical response after analysis.
All dimensions and construction information were extracted from the official FB Bombas FBEI Technical Manual. For customized performance specifications, consult the Technical Assistance Department.
The FBEI series covers 1" to 4" sizes in three casing configurations. Compare the other models’ dimensions to select the hydraulic assembly that matches your flow and viscosity.