Internal gear pump — nominal size 3" — heavy-duty 3" configuration.
Dimensions in millimeters per FBEI Technical Manual — FB Bombas
| Dimension | Value (mm) |
|---|---|
| A | 3" |
| B | 152 |
| C | 133 |
| D | 73 |
| E | 51 |
| F | 171 |
| G | 102 |
| H | 10 |
| J | 57 |
| K | 32 |
| L | 152 |
| M | 25 |
| N | 51 |
| O | 11 |
| P | 29 |
| Q | 308 |
| S | 60 |
| T | 25.40 |
| U | 25 |
| W | 13 |
| X | 40 |
Source: Official FBEI Technical Manual (Fig. 12) — all dimensions in millimeters. Missing fields do not apply to this configuration.
Per official manufacturer documentation
Positive displacement — gear within a gear (rotor + idler + crescent)
Steam must not exceed 185°C and/or 10 bar. Thermal fluid limited to 232°C and/or 10 bar (technical manual).
The AS3, AK3 and AL3 models share the same 3" nominal size but vary slightly in internal dimensions and weight — allowing fine-tuning for specific applications. All offer reinforced construction with distinct front view (manual Fig. 12). Indicated for continuous processes with high-viscosity fluids where assembly durability is critical. The choice between AS3, AK3 and AL3 should be made with FB engineering based on the fluid and operating regime.
Model-specific technical answers based on the official manual
Flow rate, pressure, speed and power are sized for each specific application (fluid, viscosity, temperature, required pressure and available NPSH). Request free technical sizing — technical response after analysis.
All dimensions and construction information were extracted from the official FB Bombas FBEI Technical Manual. For customized performance specifications, consult the Technical Assistance Department.