The FBCN-125-400 is the FBCN family model with nominal suction diameter DN150 mm and discharge DN125 mm. Standard family version. Part of the 43 standardized pumps of the FBCN series manufactured by FB Bombas in Cabreúva/SP since 1944.
The DN150 family of the FBCN series is the inflection point between standardized process duty and heavy-duty pumping. It covers large circulation water loops, medium-to-high pressure boiler feed and primary fire-fighting NFPA-20 systems. Motors typically between 75 and 200 kW.
DN150 demands rigorous NPSH analysis — on chilled-water or condensate duties the NPSHa-to-NPSHr margin is often below 1 m, mandating controlled pump positioning (dry pit or flooded suction). FB Bombas runs cavitation calculations case by case. For fire-fighting duty NFPA-20 (US standard adopted by Brazilian NBR 16704) is followed strictly with factory test listing and certified curve. For sandy raw water a wear sleeve on the impeller and mechanical seal with external clean-water flush are specified.
The FBCN series covers the standard industrial hydraulic envelope for standardized centrifugal pumps per ASME B73.1:
Q × H hydraulic envelope of the FBCN 125-400 pump at 1750 rpm, extracted from the official FBCN Technical Manual (curve CC-137.07) and bench-validated at FB Bombas test facility in Cabreúva–SP, Brazil.
Hydraulic envelope — all impellers
Overlaid H × Q curves. Each color represents one impeller diameter.
| Flow · m³/h | 102.5 | 118.5 | 130.8 | 146.1 | 159.7 | 173.5 | 188.1 | 202.2 | 215.5 | 230.5 | 243.3 | 258.0 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Head H · m | 88.1 | 88.0 | 87.9 | 87.7 | 87.5 | 87.2 | 86.9 | 86.6 | 86.2 | 85.7 | 85.3 | 84.7 |
| Flow · m³/h | 70.1 | 91.4 | 104.6 | 121.1 | 137.3 | 154.2 | 170.7 | 186.7 | 203.3 | 218.2 | 237.4 | 251.4 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Head H · m | 72.0 | 71.9 | 71.8 | 71.6 | 71.3 | 71.0 | 70.7 | 70.2 | 69.7 | 69.2 | 68.4 | 67.8 |
| Flow · m³/h | 30.6 | 54.2 | 79.0 | 102.6 | 125.9 | 149.0 | 171.3 | 194.1 | 215.1 | 240.4 | 264.4 | 288.0 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Head H · m | 66.1 | 65.9 | 65.7 | 65.3 | 64.9 | 64.4 | 63.8 | 63.0 | 62.2 | 61.1 | 60.0 | 58.7 |
| Flow · m³/h | 304.8 | 314.2 | 323.1 | 331.2 | 339.1 | 349.5 | 357.3 | 365.9 | 374.2 | 383.2 | 391.7 | 400.4 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Head H · m | 57.6 | 57.0 | 56.4 | 55.9 | 55.3 | 54.5 | 53.9 | 53.2 | 52.5 | 51.7 | 51.0 | 50.2 |
| Flow · m³/h | 79.3 | 104.4 | 129.2 | 156.8 | 180.7 | 206.6 | 232.4 | 259.0 | 285.4 | 309.9 | 337.3 | 364.2 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Head H · m | 59.0 | 58.7 | 58.3 | 57.7 | 57.0 | 56.0 | 54.9 | 53.6 | 52.0 | 50.4 | 48.3 | 46.0 |
| Flow · m³/h | 64.5 | 94.0 | 124.7 | 152.1 | 181.5 | 211.3 | 240.4 | 269.1 | 298.1 | 327.2 | 356.9 | 386.2 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Head H · m | 54.1 | 53.7 | 53.1 | 52.2 | 51.1 | 49.7 | 48.2 | 46.5 | 44.6 | 42.5 | 40.2 | 37.7 |
Corpo de forma espiral, fundido em única peça e apoiado sobre pés próprios. Possui anel de desgaste do lado da sucção.
O rotor é tipo radial, de simples sucção, possuindo um anel de desgaste no lado pressão. Exceto para os tamanhos 25-150, 32-125 e 32-125.1.
O eixo é montado com a luva de proteção na região de selagem. Pode ser utilizado gaxetas ou selo mecânico para vedação. Para fluidos com sólidos em suspensão deve ser consultado a FB.
The code FB CN 125-400 follows the official FB Bombas naming:
All dimensions in millimeters, from the official FBCN Technical Manual (page 14). Interpretation per manufacturer dimensional drawing.
FBCN Manual — Figure 7: Dimensional DrawingDimensions referenced in the table below. For other sizes refer to the complete catalog (Table 7, p.14).
| Dim. | Description | Value (mm) |
|---|---|---|
| DN1 | Suction DN | 150 |
| DN2 | Discharge DN | 125 |
| a | Shaft to suction flange distance | 140 |
| f | Total length | 530 |
| h1 | Shaft to base height | 315 |
| h2 | Total height | 400 |
| b | Foot width | 100 |
| g1 | Foot thickness | 20 |
| g2 | Auxiliary foot dimension | 6,35 |
| l1 | Alternative width | 32 |
| m1 | Longitudinal hole distance | 200 |
| m2 | Transverse hole distance | 150 |
| m3 | Foot dimension | 65 |
| n1 | Base length | 500 |
| n2 | Base width | 400 |
| n3 | Additional base distance | 152 |
| n4 | Additional base width | 110 |
| s1 | Main base hole diameter | 22 |
| s2 | Auxiliary base hole diameter | 14 |
| V | Vertical dimension | 160 |
| W | Longitudinal dimension | 370 |
| d1 (m6) | Shaft diameter (ISO m6) | 42 |
| I | Shaft end length | 110 |
| t | Keyway depth | 45,1 |
| u | Key width | 12 |
| x | x dimension | 140 |
Maximum discharge pressure limits as a function of pumped fluid temperature, by casing material and flange class (Figures 1–4 of the manual). Effective maximum pressure is always the LOWER between casing pressure and installed flange.
Pressão máxima de recalque (bar) em função da temperatura — Figura 1
Pressão máxima de recalque (bar) em função da temperatura — Figura 2
Pressão máxima de recalque (bar) em função da temperatura — Figura 2
Pressão admissível nos flanges em função da temperatura — Figura 3
Pressão admissível nos flanges em função da temperatura — Figura 3
Pressão admissível dos flanges em função da temperatura — Figura 4
Pressão admissível dos flanges em função da temperatura — Figura 4
Pressão admissível dos flanges em função da temperatura — Figura 4
Pressão admissível dos flanges em função da temperatura — Figura 4
→ ANSI B 16.1 125 Lb FF ou 250 Lb FF (ferro fundido)
→ ANSI B 16.5 / 16.42 — 150 Lb RF (aços e ferro nodular)
Casing and impeller material selection determines maximum allowable speed:
Recommended safety margins between hydraulic power absorbed by the pump and electric motor power:
The FBCN pump can be specified with different sealing chamber configurations depending on pumped fluid nature:
Lubrication by pumped fluid / internal sealing (standard for clean non-aggressive fluids)
External clean liquid sealing (toxic, aggressive, odorous fluids or vacuum suction)
External liquid lubrication and sealing (fluids with solid particles or suspended fibers)
External clean liquid flushing (fluids with abrasive particles or crystallization risk)
Thermal oil application — pure graphite or graphite-carbon fiber packing
Mechanical seals — specified per application need
The FBCN line is manufactured in adherence to the following national and international standards:
Motor elétrico, motor a diesel, etc.
Acoplamento flexível com ou sem espaçador, padrão FB ou outros fabricantes
Protetor padrão FB em aço carbono ou material anti-centelhante
Base em aço estrutural soldado
Characteristic operating window for this class: Typical flow 250–1,100 m³/h, head 25–120 m.
The FBCN pump is recommended for:
The models below share the nominal suction diameter DN150 mm and differ by impeller diameter — allowing you to select the appropriate performance curve for your application without modifying the supply piping.
FB Bombas engineering issues a detailed FBCN 125-400 data sheet with bench-verified performance curve, selected for your operating point (flow × head). Made to order in Cabreúva/SP with documented FAT.