Does FB Bombas retrofit older pumps?
By replacement, not refurbishment. FB Bombas replaces the old pump with a new, complete FB Bombas pump. Before the order, engineering assesses the installation and issues a data sheet and dimensional drawing; the drawing confirms whether the existing baseplate and piping can be kept or need adaptation.
FB Bombas does not refurbish other manufacturers’ pumps, sell third-party parts or reuse the installed casing. For FB Bombas pumps in service, it supplies original parts and maintenance contracts.
Are FB Bombas pumps delivered to Capivari with a traceable Data Book?
When the Data Book is part of the purchase scope. State which drawings and manuals are required; the proposal confirms the documents applicable to the supplied series and configuration. The same Data Book is not assumed for every pump.
Up to what viscosity can FBE pumps operate?
It depends on the size. The FBE manual (MTEC-01/01, Table 2) limits viscosity by connection size: 2,500 SSU for sizes 1/8" to 1/4", 7,500 SSU for 3/8" to 1", 50,000 SSU for 1.1/2" to 2" and 100,000 SSU for 3" to 6".
Speed decreases as viscosity rises: the drive is direct up to 7,500 SSU and, above that, by pulley or gear reducer, down to 150 rpm in the 50,000 to 100,000 SSU range. State the viscosity of the fluid for the project at start-up and operating temperatures to confirm size and speed.
What is the advantage of buying from a national manufacturer like FB Bombas?
FB Bombas serves projects from its factory, with direct engineering support and parts supply for its equipment. Availability, lead time, transport and on-site service are assessed according to the request. Its industrial pump manufacturing history began in 1944.
Is FB Bombas a national alternative to imported manufacturers in Capivari?
FB Bombas is a Brazilian manufacturer with direct service from its factory. To compare an alternative for the project, check performance, materials, dimensions, documentation and commercial conditions. Brazilian origin alone does not guarantee lower cost, shorter lead time or technical equivalence.
How to request a technical quote for industrial pumps in Capivari?
Send the application, fluid, temperature and available flow, pressure or head data. For replacement, add the equipment model, identification and drawing. Also state the destination and purchase documentation requirements. The team confirms any additional data needed and the technical and commercial proposal scope.
Is it possible to replace an imported pump with an FB Bombas pump?
Yes, once equivalence has been confirmed. FB Bombas replaces the installed pump with a complete FB Bombas pump and, before the order, assesses the installation and sends a data sheet and dimensional drawing.
For the installation, send the identification and drawing of the current pump, with its duty point, fluid, materials and drive; origin or a similar designation does not guarantee direct replacement.
What type of mechanical seal do FB Bombas pumps use?
It depends on the series. The FBE can have packing, a mechanical seal, a lip seal or a magnetic coupling; the standard seal is type 21, in ceramic, graphite and Viton, with an AISI 304 stainless-steel spring.
The FBCN uses packing or a mechanical seal, the FBOT combines graphite packing as the first sealing stage with a mechanical seal immersed in the bearing-housing oil, and the FBEI accepts packing or a single, double or cartridge mechanical seal. State the fluid, concentration, temperature and pressure of the process to define the arrangement.
How can gear pumps be evaluated for a project in Capivari?
Review FBE and FBEI to assess viscous-fluid transfer in your operation. Provide the fluid, viscosity at startup and operating temperatures, and flow and pressure requirements. Size, speed, sealing and any heating depend on the documented configuration.
Is the FBCN dimensionally compliant with ASME B73.1?
Manual MTEC-03/00 does not state that compliance: it states FBCN mechanical construction per ASME B73.1, not its dimensions. So, before a replacement, interchangeability with the existing pump is checked on each model’s drawing, together with the duty point, materials and drive.