What certifications does FB Bombas hold?
FB Bombas reports a registration in the Petrobras supplier registry. Petrobras issues the Certificado de Registro Cadastral (CRC), which replaces the former CRCC, to suppliers that meet one or more criteria of the supply family of interest; it is a supplier registration, not a product certification. Validity and supply families must be checked on the current certificate, provided on request.
How is pump sizing performed?
The review considers the fluid, flow, required pressure or head, temperature, viscosity and installation conditions. Provide what you already know and identify any equipment in use. The team checks the necessary data before confirming series, model, drive and materials.
What is the balancing grade of FB Bombas pumps for critical projects in Campo Magro?
For FBME, the impeller is statically and dynamically balanced to grade G6.3 (MSERV-08/01, item 12.2). FB Bombas does not publish a grade in the other series documents; for them and for critical projects, specify the required standard, grade and report in the purchase scope. Impeller balancing alone does not guarantee the vibration level of the installation.
Does FB Bombas serve fire protection systems?
The portfolio includes pumping sets for fire protection systems. Provide the project, duty point, drive arrangement and required standards and acceptance criteria. Compliance must be checked for the supplied set; standards such as NFPA 20 and NBR 16704 are not certificates issued for the entire company.
Does FB Bombas serve cities neighboring Campo Magro?
Yes. FB Bombas has a single factory and serves projects in other cities through its channels. Provide each project location and required scope to confirm supply and transport conditions.
How can I request a pump vibration assessment in Campo Magro?
Send the series and model of the pump installed, the operating conditions and the available vibration records; the standard, measurement points and limits are defined for the assembly, with no single limit for every pump.
Check the alignment first: the FBEI (MAN001-10) and FBME (MSERV-08/01) manuals identify pump-to-motor misalignment as a source of vibration and premature wear and call for realignment after final installation, because transport usually misaligns the set, which leaves the factory pre-aligned. The stated tolerance is under 0.05 mm radial and 0.6° angular, according to the coupling supplier.
Are FB Bombas pumps easy to maintain?
It depends on the series. On the FBCN and FBOT, back pull-out construction allows the bearing-housing assembly to be removed without disconnecting the piping, and the FBEI catalogue also indicates back pull-out construction. The FBE external gear pump is not back pull-out: its shafts are supported on bushings.
Before working on the equipment, check the series manual, the sectional drawing and the parts list.
Are replacement parts available for customers in Campo Magro?
Yes, for FB Bombas product lines. The FBE catalogue lists replacement components such as shafts, gears, bushing sets, covers, mechanical seal, lip seal and relief valve, and the FBEI (MAN001-10) and FBME (MSERV-08/01) spare-parts lists cover two years of operation. For delivery, state the series, model, manufacturing number and component; compatibility, availability and lead time are confirmed in the quotation.
Supply ships from the factory; the city page does not indicate local stock. Use original parts: the FBME service manual makes the operating and performance warranty conditional on original parts and FB Bombas’ consent.
Does FB Bombas manufacture custom pumps?
Yes, in the five Custom Solutions categories: custom complete motor-pump assembly, mobile industrial kit, industrial pump skid, retrofit with a new FB Bombas pump in place of the installed one, and special materials projects. The scope of each project is defined with engineering before manufacture.
Where can I find installation, operation and maintenance instructions for FB Bombas pumps?
It depends on the series. Installation and operation instructions are in FBEI manual MAN001-10 and in FBME service manual MSERV-08/01, which also covers maintenance and recommends supervision authorized by FB Bombas during installation.
The FBE (MTEC-01/01), FBCN (MTEC-03/00) and FBOT (MTEC-16/00) technical manuals provide technical data, sectional drawings, parts lists and dimensions; for installing and maintaining these series, the published services include on-site start-up and commissioning and maintenance contracts. The manuals are on the website’s technical manuals page (PDFs in Portuguese), and MSERV-08/01 is on the FBME series page.
For the operation, identify the series and model from the pump’s nameplate.