Skip to main content

Industrial pumps for projects in Icapuí, Ceará

Direct service from our factory in Cabreúva, Brazil. Explore FB Bombas series and tell us what your operation needs to transfer or circulate.

Start with your requirements

Do you already know the pump or need help defining it? Choose the next step for your industrial project.

Information for your project

Application context and points to confirm during technical and commercial review.

Initial guidance

For projects in Icapuí, Ceará, FB Bombas provides service from its factory in Cabreúva, Brazil. Review the industrial pump families and describe the fluid, process and operating conditions. If a pump is already installed, its model and identification help the review. Series, materials, availability and transport are confirmed for the project.

Industrial context

For industrial projects in Icapuí, FB Bombas provides direct service from its factory in Cabreúva, Brazil. A pump manufacturer since 1944, the company reviews the process, fluid and installation conditions with your team to define the equipment.

Identify the fluid by its trade name and available composition. Add viscosity at operating temperature, solids content and startup conditions. These data allow materials and sealing to be assessed before the configuration is confirmed.

State whether the requirement is an expansion, new installation or equipment replacement. For replacement, pump identification and its dimensional drawing help check the duty point and existing interfaces.

Technical criteria

The project location in Icapuí does not determine the pump series. Compare families by fluid and process, then confirm selection using flow, pressure or head, temperature, viscosity and installation conditions.

In the request for Icapuí, describe the fluid source and destination, operating duty and installation constraints. If a pump is already in use, its model and identification complement process data; they do not replace checking current conditions.

Support for Icapuí starts through the factory channels in Cabreúva, Brazil. Have the equipment identification and a description of operating conditions ready to support maintenance, spare-parts or replacement review.

Applications and operation

For economic context, IBGE records GDP of R$ 453 million for Icapuí in 2023. In the 2021 gross value added breakdown, industry accounts for approximately 31.2% and agriculture for approximately 13.8%. Reference years differ because the 2022–2023 publication does not include a sector breakdown. These data describe the municipality; pumping requirements need to be specified for your plant’s process.

To organize supply for Icapuí, state the number of pumps and each assembly’s role in the plant. Identify the duty points and operating schedule of each circuit, including the intended conditions for standby equipment.

To describe the industrial application in Icapuí, identify the process stage and whether the pump will transfer, circulate or feed another item of equipment. The same plant may have circuits with different fluid, flow, pressure and duty requirements.

If the operation in Icapuí uses different fluids, record composition, viscosity, temperature and solids content separately for each circuit. Compatibility with one product does not establish that the pump will serve every other plant process.

Source: IBGE — Municipal GDP and methodology

Supply and service

Reference distance

About 2,305 km in a straight line between the factory in Cabreúva, São Paulo, and the geographic center of the municipality (IBGE centroid). It is not a road route, freight cost or lead time.

How the distance is calculated

Haversine formula, treating the Earth as a sphere with a radius of 6,371 km, between the factory’s reference coordinates (Av. Adolpho João Traldi, 80 - Jacaré, Cabreúva-SP) and the municipal centroid published by IBGE in its Geographic Mesh API, retrieved on September 24, 2026. The centroid is a reference point of the municipal territory, not the municipal seat or the delivery location. The result is rounded to multiples of 5 km; below 20 km, only “less than 20 km” is shown.

IBGE Mesh API documentation

The project destination in Icapuí should be included in the quotation with the delivery address and access conditions. Route and transit time are confirmed for the cargo and selected carrier; distance between cities does not replace that planning.

Before dispatch to Icapuí, confirm the approved configuration, contracted documentation and delivery details with the sales team.

Send your requirements

Send your application in Icapuí to the factory team in Cabreúva, Brazil. Share the fluid, duty point and installation data you already know. Identify required drawings, manuals and tests so that documentation scope and supply conditions can be confirmed in the proposal.

Understand your application

Review process criteria and prepare the information for equipment selection.

From requirements to a technical proposal

Share what you already know. Additional details can be clarified with the team during review.

Fluid and process

What needs to be pumped, where it comes from and where it needs to go.

Operating conditions

Flow, pressure or head, temperature and operating schedule, when known.

Equipment and installation

Series, model, identification and space or connection constraints, if a pump is already installed.

Destination and supply

Project location, requested scope and documents required for your purchase.

FB Bombas factory in Cabreúva, São Paulo, Brazil

Direct service from the factory

FB Bombas is a Brazilian manufacturer with a history dating back to 1944. Our factory in Cabreúva, São Paulo, brings together CNC machining, assembly and a hydraulic test bench. The team reviews your application and confirms the configuration, documents and supply conditions in the proposal.

About FB Bombas

Review the documentation

Use the family documentation and application guides to prepare your request.

See the other pages for this city and for other cities. Service is provided by the factory in Cabreúva, Brazil.

Questions about our service

Information to help you prepare your inquiry to FB Bombas.

Are FB pumps easy to maintain?

It depends on the series. On the FBCN and FBOT, back pull-out construction allows the bearing-housing assembly to be removed without disconnecting the piping, and the FBEI catalogue also indicates back pull-out construction. The FBE external gear pump is not back pull-out: its shafts are supported on bushings. Before working on the equipment in Icapuí, check the series manual, the sectional drawing and the parts list.

Up to what temperature can FB pumps operate?

It depends on the series. The published limits are up to 260 °C for the FBCN, 350 °C for the FBOT, 340 °C for the FBEI and 140 °C for the FBME. For the FBE, the 2026 catalogue gives a range of 10 °C to 500 °C; the limit of each configuration depends on materials and sealing. These are series limits: they do not automatically apply to every model, nor do they necessarily occur together with the other maximums. State the start-up, operating and cleaning temperatures of the process in Icapuí.

Does FB Bombas serve Icapuí?

Yes. Projects in Icapuí are handled by the factory team in Cabreúva, Brazil. Send your industrial requirement and the data already available. Configuration, availability, transport and any on-site service are confirmed according to the requested scope.

What is the delivery lead time for pumps to Icapuí?

Lead time to Icapuí depends on the model, configuration and transport. Several FBE models are kept in stock; availability and expected dispatch for each item are confirmed in the quotation. State the destination and the date you need so that the proposal also defines freight and delivery responsibilities.

How can I check whether an FBCN can replace the centrifugal pump installed in Icapuí?

FB Bombas supplies the complete FBCN and checks, model by model, the dimensions in manual MTEC-03/00 (baseplate, nozzles, flanges and shaft) and the duty point before the order. The manual states mechanical construction per ASME B73.1; dimensional interchangeability with the existing pump is not assumed and is confirmed on the drawing. Send the identification and drawing of the pump installed in Icapuí, with flow, head, fluid, materials and drive.

Does FB Bombas serve cities neighboring Icapuí?

Service can be requested for Icapuí and other destinations through the factory channels in Cabreúva, Brazil. Provide each project location and required scope to confirm supply and transport conditions. This does not represent a physical FB Bombas location in every city.

Do FBCN pumps follow ASME B73.1 dimensional compliance?

No: manual MTEC-03/00 states mechanical construction per ASME B73.1, not dimensional compliance with that standard. So, before a replacement in Icapuí, interchangeability with the existing pump is checked on each model’s drawing, together with the duty point, materials and drive.

How do I request urgent spare parts for Icapuí?

With the pump and part identification. State the pump model and identification, the part as shown in the parts list of the series manual, the urgency and the destination in Icapuí; the team checks availability and confirms service and transport options. There is no published universal parts lead time or automatic guarantee of consignment stock. To reduce downtime, the FBEI (MAN001-10) and FBME (MSERV-08/01) manuals include the list of spare parts for two years of operation.

How is pump sizing performed?

The review for Icapuí considers the fluid, flow, required pressure or head, temperature, viscosity and installation conditions. Provide what you already know and identify any equipment in use. The team checks the necessary data before confirming series, model, drive and materials.

What certifications does FB Bombas hold?

FB Bombas reports a registration in the Petrobras supplier registry (CRC, formerly CRCC). It is a supplier registration, not a product certification; validity and supply families appear on the current certificate, provided on request. Technical standards depend on the series: mechanical construction per ASME B73.1 for the FBCN, NFPA 20 or ABNT NBR 16704 for FBFS fire pump sets when the project requires it, and API 610 for engineered-to-order projects. These bodies publish standards; they do not certify the company. Tests and certificates for each supply are defined in the proposal.

Tell us about your project

Send your application to our factory team. You do not need every parameter defined to start the conversation.

What happens next

The team reviews the information and confirms the details needed for a proposal. Configuration, availability, documentation, transport and lead time depend on the requested scope.

Your industrial requirements

Describe the fluid, application and project destination. Include the model and technical data you already have.

Your contact detailsEnter your contact details so we can get back to you.

A CNPJ is only required for companies in Brazil.

Include the area code. No need to repeat +55.

How can we help?Tell us about the application, your question or what needs to change in your operation.

0 / 1000 characters

Reply after we review your request