Does FB Bombas serve fire protection systems?
The portfolio includes pumping sets for fire protection systems. Provide the project, duty point, drive arrangement and required standards and acceptance criteria. Compliance must be checked for the supplied set; standards such as NFPA 20 and NBR 16704 are not certificates issued for the entire company.
What type of mechanical seal do FB Bombas pumps use?
It depends on the series. The FBE can have packing, a mechanical seal, a lip seal or a magnetic coupling; the standard seal is type 21, in ceramic, graphite and Viton, with an AISI 304 stainless-steel spring.
The FBCN uses packing or a mechanical seal, the FBOT combines graphite packing as the first sealing stage with a mechanical seal immersed in the bearing-housing oil, and the FBEI accepts packing or a single, double or cartridge mechanical seal. State the fluid, concentration, temperature and pressure of the process to define the arrangement.
How to request a pump quote for Monte Alto?
Use the website form, WhatsApp +55 11 97287-4837 or comercial@fbbombas.com.br. Describe the project, fluid and technical data you already have. The team reviews the application, clarifies missing information and confirms the configuration and proposal conditions.
Are FB Bombas pumps energy efficient?
It depends on the model and the duty point; there is no single efficiency figure for the brand. The FBCN and FBME characteristic curves show the efficiency of each model and, for stainless-steel impellers with passages up to 15 mm, the FBCN manual deducts 2 or 3 points from the curve efficiency (Table 4).
For the project, compare the absorbed power at the process flow, head and fluid, also considering drive, control and operating duty.
How long has FB Bombas been in the market?
FB Bombas began manufacturing industrial pumps in 1944. The Our History page presents the company’s development; each series’ technical documentation supports equipment evaluation for your project.
How can I check whether an FBCN can replace the centrifugal pump installed in Monte Alto?
FB Bombas supplies the complete FBCN and checks, model by model, the dimensions in manual MTEC-03/00 (baseplate, nozzles, flanges and shaft) and the duty point before the order. Mechanical construction follows ASME B73.1 (MTEC-03/00); dimensional interchangeability with the existing pump is not assumed and is confirmed on the drawing.
Send the identification and drawing of the pump installed, with flow, head, fluid, materials and drive.
Are replacement parts available for customers in Monte Alto?
Yes, for FB Bombas product lines. The FBE catalogue lists replacement components such as shafts, gears, bushing sets, covers, mechanical seal, lip seal and relief valve, and the FBEI (MAN001-10) and FBME (MSERV-08/01) spare-parts lists cover two years of operation. For delivery, state the series, model, manufacturing number and component; compatibility, availability and lead time are confirmed in the quotation.
Supply ships from the factory; the city page does not indicate local stock. Use original parts: the FBME service manual makes the operating and performance warranty conditional on original parts and FB Bombas’ consent.
Are FB Bombas pumps easy to maintain?
It depends on the series. On the FBCN and FBOT, back pull-out construction allows the bearing-housing assembly to be removed without disconnecting the piping, and the FBEI catalogue also indicates back pull-out construction. The FBE external gear pump is not back pull-out: its shafts are supported on bushings.
Before working on the equipment, check the series manual, the sectional drawing and the parts list.
How can I check pump stock for Monte Alto?
FBE pumps from 1/8″ to 4″ are kept in stock at the factory, in every configuration and option; for the FBE 5″ and 6″ and the other series, our team confirms availability together with pricing.
How to request a technical quote for industrial pumps in Monte Alto?
Send the application, fluid, temperature and available flow, pressure or head data. For replacement, add the equipment model, identification and drawing. Also state the destination and purchase documentation requirements. The team confirms any additional data needed and the technical and commercial proposal scope.