I have a series or model
Review the equipment, dimensions and family documentation. For replacement, also provide the identification of your existing pump.
View the catalog
Direct service from our factory in Cabreúva, Brazil. Explore FB Bombas series and tell us what your operation needs to transfer or circulate.
Do you already know the pump or need help defining it? Choose the next step for your industrial project.
Review the equipment, dimensions and family documentation. For replacement, also provide the identification of your existing pump.
View the catalogTell us which fluid you need to transfer or circulate and how the pump will be used. You can start the conversation without all the technical details.
Describe my applicationSelection depends on the fluid and operating conditions. Location identifies the project and delivery destination.

Standardized centrifugal pumps for industrial processes. Compare curves, nozzles and dimensions to select a model.
Explore models
Horizontal construction with multiple stages for pressure elevation. Consult curves, sizes and technical documentation.
Explore models
Pumps for thermal oil circulation in industrial heating systems. Consult the series operating conditions.
Explore modelsApplication context and points to confirm during technical and commercial review.
For projects in Espírito Santo do Pinhal, São Paulo, FB Bombas provides service from its factory in Cabreúva, Brazil. Review FBCN for industrial processes, FBME for multistage configurations and FBOT for thermal oil circulation. Selection depends on fluid, flow, head and installation conditions. Check the model curve and documentation with the team.
Describe your plant activity and the pump’s role in the process: transfer, circulation or feed. The team combines this information with fluid and installation data to guide the review of product families.
For industrial projects in Espírito Santo do Pinhal, FB Bombas provides direct service from its factory in Cabreúva, Brazil. A pump manufacturer since 1944, the company reviews the process, fluid and installation conditions with your team to define the equipment.
State whether the requirement is an expansion, new installation or equipment replacement. For replacement, pump identification and its dimensional drawing help check the duty point and existing interfaces.
For centrifugal pumps in Espírito Santo do Pinhal, check the model curve at the proposed speed and impeller diameter. Flow and head duty, suction conditions, fluid and installation interfaces need to be reviewed together before confirming the equipment.
The project location in Espírito Santo do Pinhal does not determine the pump series. Compare families by fluid and process, then confirm selection using flow, pressure or head, temperature, viscosity and installation conditions.
Support for Espírito Santo do Pinhal starts through the factory channels in Cabreúva, Brazil. Have the equipment identification and a description of operating conditions ready to support maintenance, spare-parts or replacement review.
For economic context, IBGE records GDP of R$ 2.7 billion for Espírito Santo do Pinhal in 2023. In the 2021 gross value added breakdown, industry accounts for approximately 31% and agriculture for approximately 9.5%. Reference years differ because the 2022–2023 publication does not include a sector breakdown. These data describe the municipality; pumping requirements need to be specified for your plant’s process.
To organize supply for Espírito Santo do Pinhal, state the number of pumps and each assembly’s role in the plant. Identify the duty points and operating schedule of each circuit, including the intended conditions for standby equipment.
To describe the industrial application in Espírito Santo do Pinhal, identify the process stage and whether the pump will transfer, circulate or feed another item of equipment. The same plant may have circuits with different fluid, flow, pressure and duty requirements.
If the operation in Espírito Santo do Pinhal uses different fluids, record composition, viscosity, temperature and solids content separately for each circuit. Compatibility with one product does not establish that the pump will serve every other plant process.
Source: IBGE — Municipal GDP and methodologyAbout 120 km in a straight line between the factory in Cabreúva, São Paulo, and the geographic center of the municipality (IBGE centroid). It is not a road route, freight cost or lead time.
Haversine formula, treating the Earth as a sphere with a radius of 6,371 km, between the factory’s reference coordinates (Av. Adolpho João Traldi, 80 - Jacaré, Cabreúva-SP) and the municipal centroid published by IBGE in its Geographic Mesh API, retrieved on September 24, 2026. The centroid is a reference point of the municipal territory, not the municipal seat or the delivery location. The result is rounded to multiples of 5 km; below 20 km, only “less than 20 km” is shown.
IBGE Mesh API documentationThe project destination in Espírito Santo do Pinhal should be included in the quotation with the delivery address and access conditions. Route and transit time are confirmed for the cargo and selected carrier; distance between cities does not replace that planning.
Service for Espírito Santo do Pinhal starts through the factory channels in Cabreúva, Brazil. Describe the need and equipment. Site visits, commissioning or field service depend on scope review, scheduling and commercial conditions.
To review the FBCN / FBME / FBOT families for the project in Espírito Santo do Pinhal, send the fluid and any known flow, pressure or head and temperature data. For replacement, add the installed pump’s identification and drawing. The team confirms the configuration and proposal scope.
Review process criteria and prepare the information for equipment selection.
Centrifugal pump selection for raw water intake, treated water pumping, boosters, lift stations and water and wastewater treatment processes: fluid and solids, materials, sealing arrangements, NPSH and the documented limits of the FBCN line — and where the right technology is a different one.
View applicationPump selection for acids, caustic bases, organic solvents, polymers, intermediates and pharmaceutical plant utilities — criteria for material, sealing, classified areas and the boundary between chemical service and sanitary product contact.
View applicationChilled water, condenser water, transfer and boosting have different demands. Organise thermal load, flow, head, water quality and controls to assess FBCN against actual building conditions.
View applicationHow to select the boiler feed water pump (feed and condensate return) and the hot water pump for cooling towers, building HVAC, sanitary hot water and solar heating: the three limits that must be checked separately — the pump, the sealing and the system NPSH — and what the FBCN and FBME series manuals document for each.
View applicationShare what you already know. Additional details can be clarified with the team during review.
What needs to be pumped, where it comes from and where it needs to go.
Flow, pressure or head, temperature and operating schedule, when known.
Series, model, identification and space or connection constraints, if a pump is already installed.
Project location, requested scope and documents required for your purchase.

FB Bombas is a Brazilian manufacturer with a history dating back to 1944. Our factory in Cabreúva, São Paulo, brings together CNC machining, assembly and a hydraulic test bench. The team reviews your application and confirms the configuration, documents and supply conditions in the proposal.
About FB BombasUse the family documentation and application guides to prepare your request.
Installation, operation and maintenance by series, with the document language identified.
Understand the process information needed to specify the equipment.
View applicationsSee the other pages for this city and for other cities. Service is provided by the factory in Cabreúva, Brazil.
Information to help you prepare your inquiry to FB Bombas.
No: manual MTEC-03/00 states mechanical construction per ASME B73.1, not dimensional compliance with that standard. So, before a replacement in Espírito Santo do Pinhal, interchangeability with the existing pump is checked on each model’s drawing, together with the duty point, materials and drive.
It depends on the model and the duty point; there is no single efficiency figure for the brand. The FBCN and FBME characteristic curves show the efficiency of each model and, for stainless-steel impellers with passages up to 15 mm, the FBCN manual deducts 2 or 3 points from the curve efficiency (Table 4). For the project in Espírito Santo do Pinhal, compare the absorbed power at the process flow, head and fluid, also considering drive, control and operating duty.
Send the series and model of the pump installed in Espírito Santo do Pinhal, the operating conditions and the available vibration records; the standard, measurement points and limits are defined for the assembly, with no single limit for every pump. Check the alignment first: the FBEI (MAN001-10) and FBME (MSERV-08/01) manuals identify pump-to-motor misalignment as a source of vibration and premature wear and call for realignment after final installation, because transport usually misaligns the set, which leaves the factory pre-aligned; the stated tolerance is under 0.05 mm radial and 0.6° angular, according to the coupling supplier.
Send the application in Espírito Santo do Pinhal, fluid, temperature and available flow, pressure or head data. For replacement, add the equipment model, identification and drawing. Also state the destination and purchase documentation requirements. The team confirms any additional data needed and the technical and commercial proposal scope.
It depends on the series. Installation and operation instructions are in FBEI manual MAN001-10 and in FBME service manual MSERV-08/01, which also covers maintenance and recommends FB-authorized supervision during installation. The FBE (MTEC-01/01), FBCN (MTEC-03/00) and FBOT (MTEC-16/00) technical manuals provide technical data, sectional drawings, parts lists and dimensions; for installing and maintaining these series, the published services include on-site start-up and commissioning and maintenance contracts. The manuals are on the website’s technical manuals page (PDFs in Portuguese), and MSERV-08/01 is on the FBME series page. For the operation in Espírito Santo do Pinhal, identify the series and model from the pump’s nameplate.
Yes, when they are included in the purchase scope. The published services include bench performance testing with a scope defined for the project, and on-site start-up and commissioning based on the manual and site conditions. Procedure, test points, acceptance criteria, customer witnessing and reports are defined in the proposal before the supply for Espírito Santo do Pinhal is contracted.
FB Bombas supplies the complete FBCN and checks, model by model, the dimensions in manual MTEC-03/00 (baseplate, nozzles, flanges and shaft) and the duty point before the order. The manual states mechanical construction per ASME B73.1; dimensional interchangeability with the existing pump is not assumed and is confirmed on the drawing. Send the identification and drawing of the pump installed in Espírito Santo do Pinhal, with flow, head, fluid, materials and drive.
The portfolio includes pumping sets for fire protection systems. Provide the project, duty point, drive arrangement and required standards and acceptance criteria. Compliance must be checked for the supplied set; standards such as NFPA 20 and NBR 16704 are not certificates issued for the entire company.
It depends on the series, as set out in each manual: 10 kgf/cm² for the FBE (MTEC-01/01, Table 5), 1.5 times the operating pressure for the FBOT (MTEC-16/00), 1.5 times the working pressure for the FBME (MTEC-08/01) and per ANSI B73.1 for the FBCN (MTEC-03/00). The test is performed on the factory bench in Cabreúva, Brazil; certificates, additional tests and customer witnessing are defined in the proposal for supply to Espírito Santo do Pinhal.
Warranty conditions are defined in the proposal and contract and vary with the series, operating conditions and agreement. The manuals state what can void it. Under the FBEI manual (MAN001-10), operating with a different fluid or outside the pump’s data sheets and certified documents without FB’s written authorization voids the warranty. Under the FBME service manual (MSERV-08/01), after parts are replaced, the operating and performance warranty applies only with original parts and FB’s consent. For the project in Espírito Santo do Pinhal, confirm the conditions in the quotation.
Send your application to our factory team. You do not need every parameter defined to start the conversation.
The team reviews the information and confirms the details needed for a proposal. Configuration, availability, documentation, transport and lead time depend on the requested scope.
Describe the fluid, application and project destination. Include the model and technical data you already have.