What care do pumps need in a port environment like Navegantes?
Care starts with choosing materials and coating for the equipment’s actual exposure and for the fluid.
For the FBE, the catalogue lists casing and covers in ASTM A48 CL30 cast iron, ASTM A536 ductile iron, ASTM A216 WCB carbon steel or ASTM A743 CF8M stainless steel; for FBCN, MTEC-03/00 specifies casings in cast iron, A216 WCB carbon steel and A743 CF8M stainless steel.
Describe the exposure, the project coating requirements and the fluid composition; engineering defines the configuration and documentation.
What is the warranty on FB Bombas pumps?
Warranty conditions are defined in the proposal and contract and vary with the series, operating conditions and agreement. The manuals state what can void it. Under the FBEI manual (MAN001-10), operating with a different fluid or outside the pump’s data sheets and certified documents without FB Bombas’ written authorization voids the warranty.
Under the FBME service manual (MSERV-08/01), after parts are replaced, the operating and performance warranty applies only with original parts and FB Bombas’ consent. For the project, confirm the conditions in the quotation.
What is the balancing grade of FB Bombas pumps for critical projects in Navegantes?
For FBME, the impeller is statically and dynamically balanced to grade G6.3 (MSERV-08/01, item 12.2). FB Bombas does not publish a grade in the other series documents; for them and for critical projects, specify the required standard, grade and report in the purchase scope. Impeller balancing alone does not guarantee the vibration level of the installation.
Is it possible to replace an imported pump with an FB Bombas pump?
Yes, once equivalence has been confirmed. FB Bombas replaces the installed pump with a complete FB Bombas pump and, before the order, assesses the installation and sends a data sheet and dimensional drawing.
For the installation, send the identification and drawing of the current pump, with its duty point, fluid, materials and drive; origin or a similar designation does not guarantee direct replacement.
Does FB Bombas serve fire protection systems?
The portfolio includes pumping sets for fire protection systems. Provide the project, duty point, drive arrangement and required standards and acceptance criteria. Compliance must be checked for the supplied set; standards such as NFPA 20 and NBR 16704 are not certificates issued for the entire company.
Are FB Bombas pumps energy efficient?
It depends on the model and the duty point; there is no single efficiency figure for the brand. The FBCN and FBME characteristic curves show the efficiency of each model and, for stainless-steel impellers with passages up to 15 mm, the FBCN manual deducts 2 or 3 points from the curve efficiency (Table 4).
For the project, compare the absorbed power at the process flow, head and fluid, also considering drive, control and operating duty.
Are replacement parts available for customers in Navegantes?
Yes, for FB Bombas product lines. The FBE catalogue lists replacement components such as shafts, gears, bushing sets, covers, mechanical seal, lip seal and relief valve, and the FBEI (MAN001-10) and FBME (MSERV-08/01) spare-parts lists cover two years of operation. For delivery, state the series, model, manufacturing number and component; compatibility, availability and lead time are confirmed in the quotation.
Supply ships from the factory; the city page does not indicate local stock. Use original parts: the FBME service manual makes the operating and performance warranty conditional on original parts and FB Bombas’ consent.
Are FB Bombas pumps delivered to Navegantes with a traceable Data Book?
When the Data Book is part of the purchase scope. State which drawings and manuals are required; the proposal confirms the documents applicable to the supplied series and configuration. The same Data Book is not assumed for every pump.
How to request a technical quote for industrial pumps in Navegantes?
Send the application, fluid, temperature and available flow, pressure or head data. For replacement, add the equipment model, identification and drawing. Also state the destination and purchase documentation requirements. The team confirms any additional data needed and the technical and commercial proposal scope.
How can I request a pump vibration assessment in Navegantes?
Send the series and model of the pump installed, the operating conditions and the available vibration records; the standard, measurement points and limits are defined for the assembly, with no single limit for every pump.
Check the alignment first: the FBEI (MAN001-10) and FBME (MSERV-08/01) manuals identify pump-to-motor misalignment as a source of vibration and premature wear and call for realignment after final installation, because transport usually misaligns the set, which leaves the factory pre-aligned. The stated tolerance is under 0.05 mm radial and 0.6° angular, according to the coupling supplier.