Is it possible to replace an imported pump with an FB Bombas pump?
Yes, once equivalence has been confirmed. FB Bombas replaces the installed pump with a complete FB Bombas pump and, before the order, assesses the installation and sends a data sheet and dimensional drawing.
For the installation, send the identification and drawing of the current pump, with its duty point, fluid, materials and drive; origin or a similar designation does not guarantee direct replacement.
Is the FBCN dimensionally compliant with ASME B73.1?
Manual MTEC-03/00 does not state that compliance: it states FBCN mechanical construction per ASME B73.1, not its dimensions. So, before a replacement, interchangeability with the existing pump is checked on each model’s drawing, together with the duty point, materials and drive.
How can pump delivery to Correntes be planned?
The proposal should define availability, dispatch, transport, packaging and responsibilities for delivery. State access, unloading and receiving restrictions. Route, mode and timing are confirmed for the supply; a reference distance is not a road route or delivery time.
What is the warranty on FB Bombas pumps?
Warranty conditions are defined in the proposal and contract and vary with the series, operating conditions and agreement. The manuals state what can void it. Under the FBEI manual (MAN001-10), operating with a different fluid or outside the pump’s data sheets and certified documents without FB Bombas’ written authorization voids the warranty.
Under the FBME service manual (MSERV-08/01), after parts are replaced, the operating and performance warranty applies only with original parts and FB Bombas’ consent. For the project, confirm the conditions in the quotation.
Are FB Bombas pumps easy to maintain?
It depends on the series. On the FBCN and FBOT, back pull-out construction allows the bearing-housing assembly to be removed without disconnecting the piping, and the FBEI catalogue also indicates back pull-out construction. The FBE external gear pump is not back pull-out: its shafts are supported on bushings.
Before working on the equipment, check the series manual, the sectional drawing and the parts list.
How do I request urgent spare parts for Correntes?
With the pump and part identification. State the pump model and identification, the part as shown in the parts list of the series manual, the urgency and the destination; the team checks availability and confirms service and transport options. There is no published universal parts lead time or automatic guarantee of consignment stock.
To reduce downtime, the FBEI (MAN001-10) and FBME (MSERV-08/01) manuals include the list of spare parts for two years of operation.
How can I check whether an FBCN can replace the centrifugal pump installed in Correntes?
FB Bombas supplies the complete FBCN and checks, model by model, the dimensions in manual MTEC-03/00 (baseplate, nozzles, flanges and shaft) and the duty point before the order. Mechanical construction follows ASME B73.1 (MTEC-03/00); dimensional interchangeability with the existing pump is not assumed and is confirmed on the drawing.
Send the identification and drawing of the pump installed, with flow, head, fluid, materials and drive.
Does FB Bombas manufacture custom pumps?
Yes, in the five Custom Solutions categories: custom complete motor-pump assembly, mobile industrial kit, industrial pump skid, retrofit with a new FB Bombas pump in place of the installed one, and special materials projects. The scope of each project is defined with engineering before manufacture.
Are FB Bombas pumps delivered to Correntes with a traceable Data Book?
When the Data Book is part of the purchase scope. State which drawings and manuals are required; the proposal confirms the documents applicable to the supplied series and configuration. The same Data Book is not assumed for every pump.
Are FB Bombas pumps energy efficient?
It depends on the model and the duty point; there is no single efficiency figure for the brand. The FBCN and FBME characteristic curves show the efficiency of each model and, for stainless-steel impellers with passages up to 15 mm, the FBCN manual deducts 2 or 3 points from the curve efficiency (Table 4).
For the project, compare the absorbed power at the process flow, head and fluid, also considering drive, control and operating duty.