Does FB Bombas serve fire protection systems?
The portfolio includes pumping sets for fire protection systems. Provide the project, duty point, drive arrangement and required standards and acceptance criteria. Compliance must be checked for the supplied set; standards such as NFPA 20 and NBR 16704 are not certificates issued for the entire company.
What type of mechanical seal do FB Bombas pumps use?
It depends on the series. The FBE can have packing, a mechanical seal, a lip seal or a magnetic coupling; the standard seal is type 21, in ceramic, graphite and Viton, with an AISI 304 stainless-steel spring.
The FBCN uses packing or a mechanical seal, the FBOT combines graphite packing as the first sealing stage with a mechanical seal immersed in the bearing-housing oil, and the FBEI accepts packing or a single, double or cartridge mechanical seal. State the fluid, concentration, temperature and pressure of the process to define the arrangement.
Does the cold climate around Palmital affect pump selection?
It can, especially with viscous fluids. On the FBE, speed and transmission are set by fluid viscosity (Table 2 of manual MTEC-01/01), and the heating chamber is available only on sizes from 1.1/2" to 6".
On the FBEI (MAN001-10), the fluid must be at the proper temperature and viscosity before start-up; the heating jacket must be supplied gradually, with steam up to 185 °C or thermal fluid up to 232 °C, both up to 10 bar. State the minimum site temperatures and the fluid viscosity at start-up and in operation.
What is the advantage of buying from a national manufacturer like FB Bombas?
FB Bombas serves projects from its factory, with direct engineering support and parts supply for its equipment. Availability, lead time, transport and on-site service are assessed according to the request. Its industrial pump manufacturing history began in 1944.
How do I contact FB Bombas’ technical team?
Use WhatsApp +55 11 97287-4837, telephone +55 11 4898-9200, comercial@fbbombas.com.br or the website form. To help the team, describe the application, project destination and any pump data already available.
How to request a technical quote for industrial pumps in Palmital?
Send the application, fluid, temperature and available flow, pressure or head data. For replacement, add the equipment model, identification and drawing. Also state the destination and purchase documentation requirements. The team confirms any additional data needed and the technical and commercial proposal scope.
What types of pumps does FB Bombas manufacture?
The catalogue includes FBE external gear, FBEI internal gear, FBCN standardized centrifugal, FBME multistage centrifugal and FBOT thermal oil pumps, fire systems and custom solutions. Review each family’s documentation; configuration and availability are confirmed in the quotation.
How can I request a pump vibration assessment in Palmital?
Send the series and model of the pump installed, the operating conditions and the available vibration records; the standard, measurement points and limits are defined for the assembly, with no single limit for every pump.
Check the alignment first: the FBEI (MAN001-10) and FBME (MSERV-08/01) manuals identify pump-to-motor misalignment as a source of vibration and premature wear and call for realignment after final installation, because transport usually misaligns the set, which leaves the factory pre-aligned. The stated tolerance is under 0.05 mm radial and 0.6° angular, according to the coupling supplier.
How is pump sizing performed?
The review considers the fluid, flow, required pressure or head, temperature, viscosity and installation conditions. Provide what you already know and identify any equipment in use. The team checks the necessary data before confirming series, model, drive and materials.
Up to what temperature can FB Bombas pumps operate?
It depends on the series. The published limits are up to 260 °C for the FBCN, 350 °C for the FBOT, 340 °C for the FBEI and 140 °C for the FBME. For the FBE, the 2026 catalogue gives a range of 10 °C to 500 °C; the limit of each configuration depends on materials and sealing.
These are series limits: they do not automatically apply to every model, nor do they necessarily occur together with the other maximums. State the start-up, operating and cleaning temperatures of the process.