Industrial context
The company's industry in Vila Rica helps explain the application but does not determine the pump on its own. Describe the process stage, fluid and expected result; series and material selection depends on those conditions.
Direct service from our factory in Cabreúva, Brazil. Explore FB Bombas series and tell us what your operation needs to transfer or circulate.
Do you already know the pump or need help defining it? Choose the next step for your industrial project.
Review the equipment, dimensions and family documentation. For replacement, also provide the identification of your existing pump.
Industrial pump catalogTell us the fluid and what the pump will do: transfer, circulate or feed another unit.
Describe my applicationSelection depends on the fluid and operating conditions. Location identifies the project and delivery destination.

External gear pumps for viscous fluids. From 1/8″ to 4″, in stock in every configuration: ask our team for availability and pricing.
View the models
Internal gear pumps for viscous fluid transfer. Review the configuration, materials and series documentation.
View the models
Standardized centrifugal pumps for industrial processes. Compare curves, nozzles and dimensions to select a model.
View the models
Horizontal construction with multiple stages for pressure elevation. Consult curves, sizes and technical documentation.
View the models
Pumps for thermal oil circulation in industrial heating systems. Consult the series operating conditions.
View the models
Pumping sets for fire protection systems. Review available configurations and the scope of supply.
View the models
Skids, mobile sets and custom solutions. Send your process requirements for engineering review.
View the modelsApplication context and points to confirm during technical and commercial review.
For projects in Vila Rica, Mato Grosso, FB Bombas works directly from its factory. Review the industrial pump families and describe the fluid, process and operating conditions. If a pump is already installed, its model and identification help the review. Series, materials, availability and transport are confirmed for the project.
The company's industry in Vila Rica helps explain the application but does not determine the pump on its own. Describe the process stage, fluid and expected result; series and material selection depends on those conditions.
The project location in Vila Rica does not determine the pump series. Compare families by fluid and process, then confirm selection using flow, pressure or head, temperature, viscosity and installation conditions.
To define materials for the project in Vila Rica, provide fluid composition, concentration, temperature and solids content. Also describe the external environment; the city name does not establish chemical compatibility or determine pump material.
Support for Vila Rica starts through the factory channels. Have the equipment identification and a description of operating conditions ready to support maintenance, spare-parts or replacement review.
For economic context, IBGE records GDP of R$ 921 million for Vila Rica in 2023. In the 2021 gross value added breakdown, industry accounts for approximately 3.2% and agriculture for approximately 48.7%. Reference years differ because the 2022–2023 publication does not include a sector breakdown. These data describe the municipality; pumping requirements need to be specified for your plant’s process.
To organize supply for Vila Rica, state the number of pumps and each assembly’s role in the plant. Identify the duty points and operating schedule of each circuit, including the intended conditions for standby equipment.
To describe the industrial application in Vila Rica, identify the process stage and whether the pump will transfer, circulate or feed another item of equipment. The same plant may have circuits with different fluid, flow, pressure and duty requirements.
If the operation in Vila Rica uses different fluids, record composition, viscosity, temperature and solids content separately for each circuit. Compatibility with one product does not establish that the pump will serve every other plant process.
Source: IBGE — Municipal GDP and methodologyAbout 1,545 km in a straight line between the factory in Cabreúva, São Paulo, and the geographic center of the municipality (IBGE centroid). It is not a road route, freight cost or lead time.
Haversine formula, treating the Earth as a sphere with a radius of 6,371 km, between the factory’s reference coordinates (Av. Adolpho João Traldi, 80 - Jacaré, Cabreúva-SP) and the municipal centroid published by IBGE in its Geographic Mesh API, retrieved on September 24, 2026.
The centroid is a reference point of the municipal territory, not the municipal seat or the delivery location. The result is rounded to multiples of 5 km; below 20 km, only “less than 20 km” is shown.
IBGE Mesh API documentationSend your application in Vila Rica to the factory team with the fluid, duty point and installation data. List the drawings and manuals you require: documentation scope and supply conditions are confirmed in the proposal.
Local units and persons employed in the manufacturing divisions, from largest to smallest.
| Division (CNAE) | Local units | Persons employed |
|---|---|---|
| 10 · Manufacture of food productsGuide to syrups, molasses and vegetable oils | 18 | 76 |
| 25 · Manufacture of fabricated metal products, except machinery and equipment | 14 | 53 |
| 23 · Manufacture of other non-metallic mineral products | 9 | 31 |
| 33 · Maintenance, repair and installation of machinery and equipment | 7 | 12 |
| 16 · Manufacture of wood products | 5 | 5 |
| 32 · Manufacture of miscellaneous products | 3 | 5 |
| 18 · Printing and reproduction of recorded media | 4 | 4 |
| Total manufacturing (section C) | 68 | 221 |
6 divisions are marked X, a value suppressed to protect the respondent's identity; they are excluded from the ranking.
Review process criteria and prepare the information for equipment selection.
Centrifugal pump selection for raw water intake, treated water pumping, boosters, lift stations and water and wastewater treatment processes: fluid and solids, materials, sealing arrangements, NPSH and the documented limits of the FBCN line — and where the right technology is a different one.
Pump selection for acids, caustic bases, organic solvents, polymers, intermediates and pharmaceutical plant utilities — criteria for material, sealing, classified areas and the boundary between chemical service and sanitary product contact.
Pump selection for diesel S10, gasoline C, jet fuel (QAV-1), heavy fuel oil and refinery utilities — NPSH in volatile products, classified areas and Ex certification, sealing and the FB Bombas service scope.
Chilled water, condenser water, transfer and boosting have different demands. Organise thermal load, flow, head, water quality and controls to assess FBCN against actual building conditions.
Send what you have. Engineering asks for anything missing during the review.
What needs to be pumped, where it comes from and where it needs to go.
Flow, pressure or head, temperature and operating schedule, when known.
Series, model, identification and space or connection constraints, if a pump is already installed.
Project location, requested scope and documents required for your purchase.
FB Bombas is a Brazilian manufacturer with a history dating back to 1944. Our factory in Cabreúva, São Paulo, brings together application engineering and design, CNC machining and assembly. The team reviews your application and confirms the configuration, documents and supply conditions in the proposal.
About FB BombasUse the family documentation and application guides to prepare your request.
Installation, operation and maintenance by series, with the document language identified.
Technical pump manualsUnderstand the process information needed to specify the equipment.
Industrial pump applicationsThe state page, nearby cities and cities with the same largest division by employment, with the closest number of local units in IBGE’s CEMPRE 2024.
Information to help you prepare your inquiry to FB Bombas.
The review considers the fluid, flow, required pressure or head, temperature, viscosity and installation conditions. Provide what you already know and identify any equipment in use. The team checks the necessary data before confirming series, model, drive and materials.
Yes, once equivalence has been confirmed. FB Bombas replaces the installed pump with a complete FB Bombas pump and, before the order, assesses the installation and sends a data sheet and dimensional drawing.
For the installation, send the identification and drawing of the current pump, with its duty point, fluid, materials and drive; origin or a similar designation does not guarantee direct replacement.
It depends on the series. The FBE can have packing, a mechanical seal, a lip seal or a magnetic coupling; the standard seal is type 21, in ceramic, graphite and Viton, with an AISI 304 stainless-steel spring.
The FBCN uses packing or a mechanical seal, the FBOT combines graphite packing as the first sealing stage with a mechanical seal immersed in the bearing-housing oil, and the FBEI accepts packing or a single, double or cartridge mechanical seal. State the fluid, concentration, temperature and pressure of the process to define the arrangement.
Yes, for FB Bombas product lines. The FBE catalogue lists replacement components such as shafts, gears, bushing sets, covers, mechanical seal, lip seal and relief valve, and the FBEI (MAN001-10) and FBME (MSERV-08/01) spare-parts lists cover two years of operation. For delivery, state the series, model, manufacturing number and component; compatibility, availability and lead time are confirmed in the quotation.
Supply ships from the factory; the city page does not indicate local stock. Use original parts: the FBME service manual makes the operating and performance warranty conditional on original parts and FB Bombas’ consent.
Yes. FB Bombas has a single factory and serves projects in other cities through its channels. Provide each project location and required scope to confirm supply and transport conditions.
For FBME, the impeller is statically and dynamically balanced to grade G6.3 (MSERV-08/01, item 12.2). FB Bombas does not publish a grade in the other series documents; for them and for critical projects, specify the required standard, grade and report in the purchase scope. Impeller balancing alone does not guarantee the vibration level of the installation.
It depends on the series. The catalogue for the FBE external gear pump lists oils in general, greases, asphalt, diesel oil, kerosene, paints, varnishes, resins and solvents, as well as lubrication systems and hydraulic equipment. The FBEI internal gear pump is intended for high-viscosity liquids.
The FBCN and FBME handle clean or turbid liquids, and the FBOT handles organic thermal oils free of abrasive particles and of substances that chemically attack the pump. For the process, state the composition, temperature, viscosity and solids content; fluids with suspended solids must be assessed by FB Bombas engineering.
When the Data Book is part of the purchase scope. State which drawings and manuals are required; the proposal confirms the documents applicable to the supplied series and configuration. The same Data Book is not assumed for every pump.
FB Bombas reports a registration in the Petrobras supplier registry. Petrobras issues the Certificado de Registro Cadastral (CRC), which replaces the former CRCC, to suppliers that meet one or more criteria of the supply family of interest; it is a supplier registration, not a product certification. Validity and supply families must be checked on the current certificate, provided on request.
Send the application, fluid, temperature and available flow, pressure or head data. For replacement, add the equipment model, identification and drawing. Also state the destination and purchase documentation requirements. The team confirms any additional data needed and the technical and commercial proposal scope.
Your message goes straight to the factory team.
The team reviews the information and confirms the details needed for a proposal. Configuration, availability, documentation, transport and lead time depend on the requested scope.
Describe the fluid, application and project destination. Include the model and technical data you already have.