Industrial context
Describe your plant activity and the pump’s role in the process: transfer, circulation or feed. The team combines this information with fluid and installation data to guide the review of product families.
Direct service from our factory in Cabreúva, Brazil. Explore FB Bombas series and tell us what your operation needs to transfer or circulate.
Do you already know the pump or need help defining it? Choose the next step for your industrial project.
Review the equipment, dimensions and family documentation. For replacement, also provide the identification of your existing pump.
Industrial pump catalogTell us the fluid and what the pump will do: transfer, circulate or feed another unit.
Describe my applicationSelection depends on the fluid and operating conditions. Location identifies the project and delivery destination.

External gear pumps for viscous fluids. From 1/8″ to 4″, in stock in every configuration: ask our team for availability and pricing.
View the models
Internal gear pumps for viscous fluid transfer. Review the configuration, materials and series documentation.
View the models
Standardized centrifugal pumps for industrial processes. Compare curves, nozzles and dimensions to select a model.
View the models
Horizontal construction with multiple stages for pressure elevation. Consult curves, sizes and technical documentation.
View the models
Pumps for thermal oil circulation in industrial heating systems. Consult the series operating conditions.
View the models
Pumping sets for fire protection systems. Review available configurations and the scope of supply.
View the models
Skids, mobile sets and custom solutions. Send your process requirements for engineering review.
View the modelsApplication context and points to confirm during technical and commercial review.
For projects in Bataguassu, Mato Grosso do Sul, FB Bombas works directly from its factory. Review the industrial pump families and describe the fluid, process and operating conditions. If a pump is already installed, its model and identification help the review. Series, materials, availability and transport are confirmed for the project.
Describe your plant activity and the pump’s role in the process: transfer, circulation or feed. The team combines this information with fluid and installation data to guide the review of product families.
The project location in Bataguassu does not determine the pump series. Compare families by fluid and process, then confirm selection using flow, pressure or head, temperature, viscosity and installation conditions.
To define materials for the project in Bataguassu, provide fluid composition, concentration, temperature and solids content. Also describe the external environment; the city name does not establish chemical compatibility or determine pump material.
Support for Bataguassu starts through the factory channels. Have the equipment identification and a description of operating conditions ready to support maintenance, spare-parts or replacement review.
For economic context, IBGE records GDP of R$ 1.8 billion for Bataguassu in 2023. In the 2021 gross value added breakdown, industry accounts for approximately 37.8% and agriculture for approximately 9.2%. Reference years differ because the 2022–2023 publication does not include a sector breakdown. These data describe the municipality; pumping requirements need to be specified for your plant’s process.
To organize supply for Bataguassu, state the number of pumps and each assembly’s role in the plant. Identify the duty points and operating schedule of each circuit, including the intended conditions for standby equipment.
To describe the industrial application in Bataguassu, identify the process stage and whether the pump will transfer, circulate or feed another item of equipment. The same plant may have circuits with different fluid, flow, pressure and duty requirements.
If the operation in Bataguassu uses different fluids, record composition, viscosity, temperature and solids content separately for each circuit. Compatibility with one product does not establish that the pump will serve every other plant process.
Source: IBGE — Municipal GDP and methodologyAbout 590 km in a straight line between the factory in Cabreúva, São Paulo, and the geographic center of the municipality (IBGE centroid). It is not a road route, freight cost or lead time.
Haversine formula, treating the Earth as a sphere with a radius of 6,371 km, between the factory’s reference coordinates (Av. Adolpho João Traldi, 80 - Jacaré, Cabreúva-SP) and the municipal centroid published by IBGE in its Geographic Mesh API, retrieved on September 24, 2026.
The centroid is a reference point of the municipal territory, not the municipal seat or the delivery location. The result is rounded to multiples of 5 km; below 20 km, only “less than 20 km” is shown.
IBGE Mesh API documentationSend your application in Bataguassu to the factory team with the fluid, duty point and installation data. List the drawings and manuals you require: documentation scope and supply conditions are confirmed in the proposal.
Local units and persons employed in the manufacturing divisions, from largest to smallest.
| Division (CNAE) | Local units | Persons employed |
|---|---|---|
| 10 · Manufacture of food productsGuide to syrups, molasses and vegetable oils | 30 | 2,089 |
| 32 · Manufacture of miscellaneous products | 4 | 531 |
| 25 · Manufacture of fabricated metal products, except machinery and equipment | 29 | 308 |
| 23 · Manufacture of other non-metallic mineral products | 21 | 43 |
| 33 · Maintenance, repair and installation of machinery and equipment | 8 | 25 |
| 16 · Manufacture of wood products | 6 | 17 |
| 20 · Manufacture of chemicals and chemical productsChemical and pharmaceutical process guide | 5 | 10 |
| 31 · Manufacture of furniture | 4 | 10 |
| 22 · Manufacture of rubber and plastics products | 3 | 6 |
| 14 · Manufacture of wearing apparel and accessories | 3 | 1 |
| Total manufacturing (section C) | 122 | 3,305 |
7 divisions are marked X, a value suppressed to protect the respondent's identity; they are excluded from the ranking.
Review process criteria and prepare the information for equipment selection.
Centrifugal pump selection for raw water intake, treated water pumping, boosters, lift stations and water and wastewater treatment processes: fluid and solids, materials, sealing arrangements, NPSH and the documented limits of the FBCN line — and where the right technology is a different one.
Pump selection for acids, caustic bases, organic solvents, polymers, intermediates and pharmaceutical plant utilities — criteria for material, sealing, classified areas and the boundary between chemical service and sanitary product contact.
Pump selection for diesel S10, gasoline C, jet fuel (QAV-1), heavy fuel oil and refinery utilities — NPSH in volatile products, classified areas and Ex certification, sealing and the FB Bombas service scope.
Chilled water, condenser water, transfer and boosting have different demands. Organise thermal load, flow, head, water quality and controls to assess FBCN against actual building conditions.
Send what you have. Engineering asks for anything missing during the review.
What needs to be pumped, where it comes from and where it needs to go.
Flow, pressure or head, temperature and operating schedule, when known.
Series, model, identification and space or connection constraints, if a pump is already installed.
Project location, requested scope and documents required for your purchase.
FB Bombas is a Brazilian manufacturer with a history dating back to 1944. Our factory in Cabreúva, São Paulo, brings together application engineering and design, CNC machining and assembly. The team reviews your application and confirms the configuration, documents and supply conditions in the proposal.
About FB BombasUse the family documentation and application guides to prepare your request.
Installation, operation and maintenance by series, with the document language identified.
Technical pump manualsUnderstand the process information needed to specify the equipment.
Industrial pump applicationsThe state page, nearby cities and cities with the same largest division by employment, with the closest number of local units in IBGE’s CEMPRE 2024.
Information to help you prepare your inquiry to FB Bombas.
Send the series and model of the pump installed, the operating conditions and the available vibration records; the standard, measurement points and limits are defined for the assembly, with no single limit for every pump.
Check the alignment first: the FBEI (MAN001-10) and FBME (MSERV-08/01) manuals identify pump-to-motor misalignment as a source of vibration and premature wear and call for realignment after final installation, because transport usually misaligns the set, which leaves the factory pre-aligned. The stated tolerance is under 0.05 mm radial and 0.6° angular, according to the coupling supplier.
FB Bombas serves projects from its factory, with direct engineering support and parts supply for its equipment. Availability, lead time, transport and on-site service are assessed according to the request. Its industrial pump manufacturing history began in 1944.
Warranty conditions are defined in the proposal and contract and vary with the series, operating conditions and agreement. The manuals state what can void it. Under the FBEI manual (MAN001-10), operating with a different fluid or outside the pump’s data sheets and certified documents without FB Bombas’ written authorization voids the warranty.
Under the FBME service manual (MSERV-08/01), after parts are replaced, the operating and performance warranty applies only with original parts and FB Bombas’ consent. For the project, confirm the conditions in the quotation.
Send the application, fluid, temperature and available flow, pressure or head data. For replacement, add the equipment model, identification and drawing. Also state the destination and purchase documentation requirements. The team confirms any additional data needed and the technical and commercial proposal scope.
Yes. FB Bombas has a single factory and serves projects in other cities through its channels. Provide each project location and required scope to confirm supply and transport conditions.
The review considers the fluid, flow, required pressure or head, temperature, viscosity and installation conditions. Provide what you already know and identify any equipment in use. The team checks the necessary data before confirming series, model, drive and materials.
Manual MTEC-03/00 does not state that compliance: it states FBCN mechanical construction per ASME B73.1, not its dimensions. So, before a replacement, interchangeability with the existing pump is checked on each model’s drawing, together with the duty point, materials and drive.
Yes, for FB Bombas product lines. The FBE catalogue lists replacement components such as shafts, gears, bushing sets, covers, mechanical seal, lip seal and relief valve, and the FBEI (MAN001-10) and FBME (MSERV-08/01) spare-parts lists cover two years of operation. For delivery, state the series, model, manufacturing number and component; compatibility, availability and lead time are confirmed in the quotation.
Supply ships from the factory; the city page does not indicate local stock. Use original parts: the FBME service manual makes the operating and performance warranty conditional on original parts and FB Bombas’ consent.
The catalogue includes FBE external gear, FBEI internal gear, FBCN standardized centrifugal, FBME multistage centrifugal and FBOT thermal oil pumps, fire systems and custom solutions. Review each family’s documentation; configuration and availability are confirmed in the quotation.
With the pump and part identification. State the pump model and identification, the part as shown in the parts list of the series manual, the urgency and the destination; the team checks availability and confirms service and transport options. There is no published universal parts lead time or automatic guarantee of consignment stock.
To reduce downtime, the FBEI (MAN001-10) and FBME (MSERV-08/01) manuals include the list of spare parts for two years of operation.
Your message goes straight to the factory team.
The team reviews the information and confirms the details needed for a proposal. Configuration, availability, documentation, transport and lead time depend on the requested scope.
Describe the fluid, application and project destination. Include the model and technical data you already have.