Up to what temperature can FB Bombas pumps operate?
It depends on the series. The published limits are up to 260 °C for the FBCN, 350 °C for the FBOT, 340 °C for the FBEI and 140 °C for the FBME. For the FBE, the 2026 catalogue gives a range of 10 °C to 500 °C; the limit of each configuration depends on materials and sealing.
These are series limits: they do not automatically apply to every model, nor do they necessarily occur together with the other maximums. State the start-up, operating and cleaning temperatures of the process.
How can I request a pump vibration assessment in Pereiro?
Send the series and model of the pump installed, the operating conditions and the available vibration records; the standard, measurement points and limits are defined for the assembly, with no single limit for every pump.
Check the alignment first: the FBEI (MAN001-10) and FBME (MSERV-08/01) manuals identify pump-to-motor misalignment as a source of vibration and premature wear and call for realignment after final installation, because transport usually misaligns the set, which leaves the factory pre-aligned. The stated tolerance is under 0.05 mm radial and 0.6° angular, according to the coupling supplier.
Does FB Bombas serve cities neighboring Pereiro?
Yes. FB Bombas has a single factory and serves projects in other cities through its channels. Provide each project location and required scope to confirm supply and transport conditions.
How can I check pump stock for Pereiro?
FBE pumps from 1/8″ to 4″ are kept in stock at the factory, in every configuration and option; for the FBE 5″ and 6″ and the other series, our team confirms availability together with pricing.
How do I request urgent spare parts for Pereiro?
With the pump and part identification. State the pump model and identification, the part as shown in the parts list of the series manual, the urgency and the destination; the team checks availability and confirms service and transport options. There is no published universal parts lead time or automatic guarantee of consignment stock.
To reduce downtime, the FBEI (MAN001-10) and FBME (MSERV-08/01) manuals include the list of spare parts for two years of operation.
How can I check whether a pump purchase for Pereiro can use BNDES Finame?
Following the BNDES steps, first check whether the equipment appears on the list of items eligible for BNDES Finame financing, in the CFI Catalog on the bank’s website; for that check, ask the sales team for the identification of the model quoted.
Then apply for financing through an accredited financial agent, such as a commercial bank, development bank, development agency or credit union. The agent reviews the request and, if it approves the operation, forwards it to BNDES, which evaluates the request and authorizes the financing. Being a Brazilian manufacturer does not, on its own, show that the equipment is accredited.
Is FB Bombas a national alternative to imported manufacturers in Pereiro?
FB Bombas is a Brazilian manufacturer with direct service from its factory. To compare an alternative for the project, check performance, materials, dimensions, documentation and commercial conditions. Brazilian origin alone does not guarantee lower cost, shorter lead time or technical equivalence.
What certifications does FB Bombas hold?
FB Bombas reports a registration in the Petrobras supplier registry. Petrobras issues the Certificado de Registro Cadastral (CRC), which replaces the former CRCC, to suppliers that meet one or more criteria of the supply family of interest; it is a supplier registration, not a product certification. Validity and supply families must be checked on the current certificate, provided on request.
What is the balancing grade of FB Bombas pumps for critical projects in Pereiro?
For FBME, the impeller is statically and dynamically balanced to grade G6.3 (MSERV-08/01, item 12.2). FB Bombas does not publish a grade in the other series documents; for them and for critical projects, specify the required standard, grade and report in the purchase scope. Impeller balancing alone does not guarantee the vibration level of the installation.
Is the FBCN dimensionally compliant with ASME B73.1?
Manual MTEC-03/00 does not state that compliance: it states FBCN mechanical construction per ASME B73.1, not its dimensions. So, before a replacement, interchangeability with the existing pump is checked on each model’s drawing, together with the duty point, materials and drive.