Does FB Bombas serve cities neighboring Lapão?
Yes. FB Bombas has a single factory and serves projects in other cities through its channels. Provide each project location and required scope to confirm supply and transport conditions.
Is the FBCN dimensionally compliant with ASME B73.1?
Manual MTEC-03/00 does not state that compliance: it states FBCN mechanical construction per ASME B73.1, not its dimensions. So, before a replacement, interchangeability with the existing pump is checked on each model’s drawing, together with the duty point, materials and drive.
What is the warranty on FB Bombas pumps?
Warranty conditions are defined in the proposal and contract and vary with the series, operating conditions and agreement. The manuals state what can void it. Under the FBEI manual (MAN001-10), operating with a different fluid or outside the pump’s data sheets and certified documents without FB Bombas’ written authorization voids the warranty.
Under the FBME service manual (MSERV-08/01), after parts are replaced, the operating and performance warranty applies only with original parts and FB Bombas’ consent. For the project, confirm the conditions in the quotation.
Are FB Bombas pumps delivered to Lapão with a traceable Data Book?
When the Data Book is part of the purchase scope. State which drawings and manuals are required; the proposal confirms the documents applicable to the supplied series and configuration. The same Data Book is not assumed for every pump.
How is pump sizing performed?
The review considers the fluid, flow, required pressure or head, temperature, viscosity and installation conditions. Provide what you already know and identify any equipment in use. The team checks the necessary data before confirming series, model, drive and materials.
Are FB Bombas pumps energy efficient?
It depends on the model and the duty point; there is no single efficiency figure for the brand. The FBCN and FBME characteristic curves show the efficiency of each model and, for stainless-steel impellers with passages up to 15 mm, the FBCN manual deducts 2 or 3 points from the curve efficiency (Table 4).
For the project, compare the absorbed power at the process flow, head and fluid, also considering drive, control and operating duty.
How can I request a pump vibration assessment in Lapão?
Send the series and model of the pump installed, the operating conditions and the available vibration records; the standard, measurement points and limits are defined for the assembly, with no single limit for every pump.
Check the alignment first: the FBEI (MAN001-10) and FBME (MSERV-08/01) manuals identify pump-to-motor misalignment as a source of vibration and premature wear and call for realignment after final installation, because transport usually misaligns the set, which leaves the factory pre-aligned. The stated tolerance is under 0.05 mm radial and 0.6° angular, according to the coupling supplier.
Does FB Bombas retrofit older pumps?
By replacement, not refurbishment. FB Bombas replaces the old pump with a new, complete FB Bombas pump. Before the order, engineering assesses the installation and issues a data sheet and dimensional drawing; the drawing confirms whether the existing baseplate and piping can be kept or need adaptation.
FB Bombas does not refurbish other manufacturers’ pumps, sell third-party parts or reuse the installed casing. For FB Bombas pumps in service, it supplies original parts and maintenance contracts.
Up to what temperature can FB Bombas pumps operate?
It depends on the series. The published limits are up to 260 °C for the FBCN, 350 °C for the FBOT, 340 °C for the FBEI and 140 °C for the FBME. For the FBE, the 2026 catalogue gives a range of 10 °C to 500 °C; the limit of each configuration depends on materials and sealing.
These are series limits: they do not automatically apply to every model, nor do they necessarily occur together with the other maximums. State the start-up, operating and cleaning temperatures of the process.
What types of pumps does FB Bombas manufacture?
The catalogue includes FBE external gear, FBEI internal gear, FBCN standardized centrifugal, FBME multistage centrifugal and FBOT thermal oil pumps, fire systems and custom solutions. Review each family’s documentation; configuration and availability are confirmed in the quotation.