Skip to main content

Known series or pump to be selected

Do you already know the pump or need help defining it? Choose the next step for your industrial project.

I have a series or model

Review the equipment, dimensions and family documentation. For replacement, also provide the identification of your existing pump.

Industrial pump catalog

I need to select a pump

Tell us the fluid and what the pump will do: transfer, circulate or feed another unit.

Describe my application

Information for your project

Application context and points to confirm during technical and commercial review.

Initial guidance

For projects in Guanambi, Bahia, FB Bombas works directly from its factory. Review the industrial pump families and describe the fluid, process and operating conditions. If a pump is already installed, its model and identification help the review. Series, materials, availability and transport are confirmed for the project.

Industrial context

Identify the fluid by its trade name and available composition. Add viscosity at operating temperature, solids content and startup conditions. These data allow materials and sealing to be assessed before the configuration is confirmed.

Technical criteria

In the request for Guanambi, describe the fluid source and destination, operating duty and installation constraints. If a pump is already in use, its model and identification complement process data; they do not replace checking current conditions.

Provide the standards and acceptance criteria required for the project in Guanambi. Documentation should identify the supplied series and configuration and requirements met. A design standard and a company certificate serve different purposes.

Support for Guanambi starts through the factory channels. Have the equipment identification and a description of operating conditions ready to support maintenance, spare-parts or replacement review.

Applications and operation

For economic context, IBGE records GDP of R$ 2 billion for Guanambi in 2023. In the 2021 gross value added breakdown, industry accounts for approximately 14.1% and agriculture for approximately 3.9%. Reference years differ because the 2022–2023 publication does not include a sector breakdown. These data describe the municipality; pumping requirements need to be specified for your plant’s process.

To organize supply for Guanambi, state the number of pumps and each assembly’s role in the plant. Identify the duty points and operating schedule of each circuit, including the intended conditions for standby equipment.

To describe the industrial application in Guanambi, identify the process stage and whether the pump will transfer, circulate or feed another item of equipment. The same plant may have circuits with different fluid, flow, pressure and duty requirements.

If the operation in Guanambi uses different fluids, record composition, viscosity, temperature and solids content separately for each circuit. Compatibility with one product does not establish that the pump will serve every other plant process.

Source: IBGE — Municipal GDP and methodology

Supply and service

Reference distance

About 1,100 km in a straight line between the factory in Cabreúva, São Paulo, and the geographic center of the municipality (IBGE centroid). It is not a road route, freight cost or lead time.

How the distance is calculated

Haversine formula, treating the Earth as a sphere with a radius of 6,371 km, between the factory’s reference coordinates (Av. Adolpho João Traldi, 80 - Jacaré, Cabreúva-SP) and the municipal centroid published by IBGE in its Geographic Mesh API, retrieved on September 24, 2026.

The centroid is a reference point of the municipal territory, not the municipal seat or the delivery location. The result is rounded to multiples of 5 km; below 20 km, only “less than 20 km” is shown.

IBGE Mesh API documentation

Replacement, supply and receiving guidance for this state.

Data for review

Send your application in Guanambi to the factory team with the fluid, duty point and installation data. List the drawings and manuals you require: documentation scope and supply conditions are confirmed in the proposal.

Local industry in numbers

Local units and persons employed in the manufacturing divisions, from largest to smallest.

Industrial profile of Guanambi — 2024
Division (CNAE)Local unitsPersons employed
10 · Manufacture of food productsGuide to syrups, molasses and vegetable oils60499
23 · Manufacture of other non-metallic mineral products61314
25 · Manufacture of fabricated metal products, except machinery and equipment39183
31 · Manufacture of furniture29147
16 · Manufacture of wood products16139
13 · Manufacture of textiles27122
33 · Maintenance, repair and installation of machinery and equipment16110
14 · Manufacture of wearing apparel and accessories1676
18 · Printing and reproduction of recorded media2172
32 · Manufacture of miscellaneous products1438
20 · Manufacture of chemicals and chemical productsChemical and pharmaceutical process guide636
22 · Manufacture of rubber and plastics products433
28 · Manufacture of machinery and equipment331
29 · Manufacture of motor vehicles, trailers and semi-trailers826
27 · Manufacture of electrical machinery, apparatus and materials612
Total manufacturing (section C)3301,848

3 divisions are marked X, a value suppressed to protect the respondent's identity; they are excluded from the ranking.

Source: IBGE, Central Business Register 2024 (table 9528).

Understand your application

Review process criteria and prepare the information for equipment selection.

What to send for a technical proposal

Send what you have. Engineering asks for anything missing during the review.

  1. Fluid and process

    What needs to be pumped, where it comes from and where it needs to go.

  2. Operating conditions

    Flow, pressure or head, temperature and operating schedule, when known.

  3. Equipment and installation

    Series, model, identification and space or connection constraints, if a pump is already installed.

  4. Destination and supply

    Project location, requested scope and documents required for your purchase.

Direct service from the factory

FB Bombas is a Brazilian manufacturer with a history dating back to 1944. Our factory in Cabreúva, São Paulo, brings together application engineering and design, CNC machining and assembly. The team reviews your application and confirms the configuration, documents and supply conditions in the proposal.

About FB Bombas

Manuals and guides by series and application

Use the family documentation and application guides to prepare your request.

Technical manuals

Installation, operation and maintenance by series, with the document language identified.

Technical pump manuals

The state page, nearby cities and cities with the same largest division by employment, with the closest number of local units in IBGE’s CEMPRE 2024.

Questions about our service

Information to help you prepare your inquiry to FB Bombas.

Does FB Bombas retrofit older pumps?

By replacement, not refurbishment. FB Bombas replaces the old pump with a new, complete FB Bombas pump. Before the order, engineering assesses the installation and issues a data sheet and dimensional drawing; the drawing confirms whether the existing baseplate and piping can be kept or need adaptation.

FB Bombas does not refurbish other manufacturers’ pumps, sell third-party parts or reuse the installed casing. For FB Bombas pumps in service, it supplies original parts and maintenance contracts.

How do I request urgent spare parts for Guanambi?

With the pump and part identification. State the pump model and identification, the part as shown in the parts list of the series manual, the urgency and the destination; the team checks availability and confirms service and transport options. There is no published universal parts lead time or automatic guarantee of consignment stock.

To reduce downtime, the FBEI (MAN001-10) and FBME (MSERV-08/01) manuals include the list of spare parts for two years of operation.

How is pump sizing performed?

The review considers the fluid, flow, required pressure or head, temperature, viscosity and installation conditions. Provide what you already know and identify any equipment in use. The team checks the necessary data before confirming series, model, drive and materials.

How can I check pump stock for Guanambi?

FBE pumps from 1/8″ to 4″ are kept in stock at the factory, in every configuration and option; for the FBE 5″ and 6″ and the other series, our team confirms availability together with pricing.

How can I check whether an FBCN can replace the centrifugal pump installed in Guanambi?

FB Bombas supplies the complete FBCN and checks, model by model, the dimensions in manual MTEC-03/00 (baseplate, nozzles, flanges and shaft) and the duty point before the order. Mechanical construction follows ASME B73.1 (MTEC-03/00); dimensional interchangeability with the existing pump is not assumed and is confirmed on the drawing.

Send the identification and drawing of the pump installed, with flow, head, fluid, materials and drive.

Are replacement parts available for customers in Guanambi?

Yes, for FB Bombas product lines. The FBE catalogue lists replacement components such as shafts, gears, bushing sets, covers, mechanical seal, lip seal and relief valve, and the FBEI (MAN001-10) and FBME (MSERV-08/01) spare-parts lists cover two years of operation. For delivery, state the series, model, manufacturing number and component; compatibility, availability and lead time are confirmed in the quotation.

Supply ships from the factory; the city page does not indicate local stock. Use original parts: the FBME service manual makes the operating and performance warranty conditional on original parts and FB Bombas’ consent.

Are FB Bombas pumps energy efficient?

It depends on the model and the duty point; there is no single efficiency figure for the brand. The FBCN and FBME characteristic curves show the efficiency of each model and, for stainless-steel impellers with passages up to 15 mm, the FBCN manual deducts 2 or 3 points from the curve efficiency (Table 4).

For the project, compare the absorbed power at the process flow, head and fluid, also considering drive, control and operating duty.

How long has FB Bombas been in the market?

FB Bombas began manufacturing industrial pumps in 1944. The Our History page presents the company’s development; each series’ technical documentation supports equipment evaluation for your project.

How can I request a pump vibration assessment in Guanambi?

Send the series and model of the pump installed, the operating conditions and the available vibration records; the standard, measurement points and limits are defined for the assembly, with no single limit for every pump.

Check the alignment first: the FBEI (MAN001-10) and FBME (MSERV-08/01) manuals identify pump-to-motor misalignment as a source of vibration and premature wear and call for realignment after final installation, because transport usually misaligns the set, which leaves the factory pre-aligned. The stated tolerance is under 0.05 mm radial and 0.6° angular, according to the coupling supplier.

Up to what temperature can FB Bombas pumps operate?

It depends on the series. The published limits are up to 260 °C for the FBCN, 350 °C for the FBOT, 340 °C for the FBEI and 140 °C for the FBME. For the FBE, the 2026 catalogue gives a range of 10 °C to 500 °C; the limit of each configuration depends on materials and sealing.

These are series limits: they do not automatically apply to every model, nor do they necessarily occur together with the other maximums. State the start-up, operating and cleaning temperatures of the process.

Send your process data to engineering in Cabreúva

Your message goes straight to the factory team.

What happens next

The team reviews the information and confirms the details needed for a proposal. Configuration, availability, documentation, transport and lead time depend on the requested scope.

Application details

Describe the fluid, application and project destination. Include the model and technical data you already have.

Your contact detailsComplete the fields marked as required.

Include the area code. No need to repeat +55.

Fluid, application or model, if you already know it.

Our team replies with the quote or with any questions we still have.