Are FB Bombas pumps easy to maintain?
It depends on the series. On the FBCN and FBOT, back pull-out construction allows the bearing-housing assembly to be removed without disconnecting the piping, and the FBEI catalogue also indicates back pull-out construction. The FBE external gear pump is not back pull-out: its shafts are supported on bushings.
Before working on the equipment, check the series manual, the sectional drawing and the parts list.
Does FB Bombas retrofit older pumps?
By replacement, not refurbishment. FB Bombas replaces the old pump with a new, complete FB Bombas pump. Before the order, engineering assesses the installation and issues a data sheet and dimensional drawing; the drawing confirms whether the existing baseplate and piping can be kept or need adaptation.
FB Bombas does not refurbish other manufacturers’ pumps, sell third-party parts or reuse the installed casing. For FB Bombas pumps in service, it supplies original parts and maintenance contracts.
How is pump sizing performed?
The review considers the fluid, flow, required pressure or head, temperature, viscosity and installation conditions. Provide what you already know and identify any equipment in use. The team checks the necessary data before confirming series, model, drive and materials.
What types of fluids can FB Bombas pumps handle?
It depends on the series. The catalogue for the FBE external gear pump lists oils in general, greases, asphalt, diesel oil, kerosene, paints, varnishes, resins and solvents, as well as lubrication systems and hydraulic equipment. The FBEI internal gear pump is intended for high-viscosity liquids.
The FBCN and FBME handle clean or turbid liquids, and the FBOT handles organic thermal oils free of abrasive particles and of substances that chemically attack the pump. For the process, state the composition, temperature, viscosity and solids content; fluids with suspended solids must be assessed by FB Bombas engineering.
Are FB Bombas pumps energy efficient?
It depends on the model and the duty point; there is no single efficiency figure for the brand. The FBCN and FBME characteristic curves show the efficiency of each model and, for stainless-steel impellers with passages up to 15 mm, the FBCN manual deducts 2 or 3 points from the curve efficiency (Table 4).
For the project, compare the absorbed power at the process flow, head and fluid, also considering drive, control and operating duty.
How long has FB Bombas been in the market?
FB Bombas began manufacturing industrial pumps in 1944. The Our History page presents the company’s development; each series’ technical documentation supports equipment evaluation for your project.
How can I check whether an FBCN can replace the centrifugal pump installed in Jutaí?
FB Bombas supplies the complete FBCN and checks, model by model, the dimensions in manual MTEC-03/00 (baseplate, nozzles, flanges and shaft) and the duty point before the order. Mechanical construction follows ASME B73.1 (MTEC-03/00); dimensional interchangeability with the existing pump is not assumed and is confirmed on the drawing.
Send the identification and drawing of the pump installed, with flow, head, fluid, materials and drive.
What types of pumps does FB Bombas manufacture?
The catalogue includes FBE external gear, FBEI internal gear, FBCN standardized centrifugal, FBME multistage centrifugal and FBOT thermal oil pumps, fire systems and custom solutions. Review each family’s documentation; configuration and availability are confirmed in the quotation.
Does FB Bombas manufacture custom pumps?
Yes, in the five Custom Solutions categories: custom complete motor-pump assembly, mobile industrial kit, industrial pump skid, retrofit with a new FB Bombas pump in place of the installed one, and special materials projects. The scope of each project is defined with engineering before manufacture.
What is the balancing grade of FB Bombas pumps for critical projects in Jutaí?
For FBME, the impeller is statically and dynamically balanced to grade G6.3 (MSERV-08/01, item 12.2). FB Bombas does not publish a grade in the other series documents; for them and for critical projects, specify the required standard, grade and report in the purchase scope. Impeller balancing alone does not guarantee the vibration level of the installation.