Standardized centrifugal pump FBCN 80-200. Suction DN125, discharge DN80. Dimensional catalog model.

Check the 500 mm length, 250 mm height and mounting dimensions before assessing the installation. The full table, material-specific weights and curves below apply to reference 80-200.
The overall series limits do not define this model’s operating point. Confirm flow, head, impeller, material and sealing with engineering.
Series rating FBCN: 4.8/5 · 45 customer ratings
Consolidated figures supplied by FB Bombas from its customer ratings spreadsheet. The score and count refer to the series; they are not independent counts for each model or configuration.
Designed for clean or turbid liquids. Applications listed in the manual (p. 1):
Table 1 of manual MTEC-03/00 (p. 5); length and height from Table 7 (p. 14).
Dimensions in millimeters from the FBCN Technical Manual, Table 7 (p. 14). Check the references against the dimensional drawing (p. 13).
| Dim. | Description | Value (mm) |
|---|---|---|
| Pump dimensions | ||
| DN1 | Suction DN | 125 |
| DN2 | Discharge DN | 80 |
| a | Shaft to suction flange distance | 125 |
| f | Total length | 500 |
| h1 | Shaft to base height | 180 |
| h2 | Total height | 250 |
| Foot dimensions | ||
| b | Foot width | 65 |
| g1 | Foot thickness | 18 |
| g2 | Auxiliary foot dimension | 6.35 |
| l1 | Alternative width | 32 |
| m1 | Longitudinal hole distance | 125 |
| m2 | Transverse hole distance | 95 |
| m3 | Foot dimension | 65 |
| n1 | Base length | 345 |
| n2 | Base width | 280 |
| n3 | Additional base distance | 152 |
| n4 | Additional base width | 110 |
| s1 | Main base hole diameter | 14 |
| s2 | Auxiliary base hole diameter | 14 |
| V | Vertical dimension | 130 |
| W | Longitudinal dimension | 370 |
| Shaft end | ||
| d1 (m6) | Shaft diameter (ISO m6) | 32 |
| I | Shaft end length | 80 |
| t | Keyway depth | 35.3 |
| u | Key width | 10 |
| x | x dimension | 140 |
5 impellers with points · Ø 179–219 mm · CC-196.07
FBCN 80-200 · CC-196.07. Reference plot extracted from the FB Bombas technical catalog. Q × H points below apply at the stated speed. Confirm the operating point and impeller with engineering.
| Flow Q (m³/h) | Head H (m) |
|---|---|
| 0 | 24.0 |
| 40 | 24.0 |
| 68 | 23.5 |
| 90 | 22.7 |
| 110 | 21.6 |
| 128 | 20.2 |
| 144 | 18.5 |
| 160 | 16.5 |
| Flow Q (m³/h) | Head H (m) |
|---|---|
| 0 | 21.9 |
| 36 | 21.8 |
| 60 | 21.5 |
| 82 | 20.7 |
| 102 | 19.6 |
| 120 | 18.2 |
| 136 | 16.6 |
| 150 | 14.9 |
| Flow Q (m³/h) | Head H (m) |
|---|---|
| 0 | 19.7 |
| 44 | 19.4 |
| 66 | 18.9 |
| 84 | 18.3 |
| 100 | 17.4 |
| 114 | 16.2 |
| 128 | 14.8 |
| 140 | 13.3 |
| Flow Q (m³/h) | Head H (m) |
|---|---|
| 0 | 17.9 |
| 34 | 17.6 |
| 56 | 17.2 |
| 76 | 16.5 |
| 94 | 15.5 |
| 110 | 14.3 |
| 126 | 12.7 |
| 140 | 11.0 |
| Flow Q (m³/h) | Head H (m) |
|---|---|
| 0 | 15.9 |
| 26 | 15.9 |
| 46 | 15.6 |
| 66 | 15.1 |
| 84 | 14.2 |
| 100 | 13.2 |
| 116 | 11.9 |
| 130 | 10.4 |
Q × H points read from the official sheet for every impeller plotted, from shutoff (Q = 0) to the end of each trace.
Shaft power, NPSHr and efficiency at the operating point must be confirmed in the engineering data sheet. The reference curve does not replace technical selection.
Open sheet CC-196.07 in the curve catalog (PDF, p. 27)Limits from manual MTEC-03/00 for this size and for the series. Confirm the operating point, material and sealing with engineering.
Maximum discharge pressure curves (Figures 1 and 2): From −30 to 160 °C for the cast iron casing and from −50 to 260 °C for the carbon steel and stainless steel casing.
| Shaft sealing | Temperature | ANSI B16.1 flanges · 125 lb | ANSI B16.1 flanges · 250 lb |
|---|---|---|---|
| Packing | −28 to 65 °C | 12 bar | 16 bar |
| 93 °C | 11 bar | 16 bar | |
| 105 °C | 10 bar | 16 bar | |
| Mechanical seal | 90 °C | 10 bar | 10 bar |
| Pumping temperature | Cooling flow |
|---|---|
| 140 °C | 2.3 l/min |
| 160 °C | 2.6 l/min |
| 200 °C | 3.3 l/min |
| 250 °C | 4.0 l/min |
| 350 °C | 5.0 l/min |
| Material or flange | Temperature | Pressure |
|---|---|---|
| Cast iron | −30 to 120 °C | 16 bar |
| 120 to 160 °C | ↘ Fig. 1 | |
| Carbon steel A216 WCB | −50 to 120 °C | 24 bar |
| 120 to 260 °C | ↘ Fig. 2 | |
| Stainless steel A743 CF8M | −50 to 80 °C | 16 bar |
| 80 to 260 °C | ↘ Fig. 2 | |
| Flanges ANSI B16.1 · 125 lb | −30 to 65 °C | 12.5 bar |
| 65 to 260 °C | ↘ Fig. 3 | |
| Flanges ANSI B16.1 · 250 lb | −30 to 80 °C | 28 bar |
| 80 to 260 °C | ↘ Fig. 3 | |
| Flanges ANSI B16.5 · 150 lb WCB | −30 to 65 °C | 19.5 bar |
| 65 to 260 °C | ↘ Fig. 4 | |
| Flanges ANSI B16.5 · 150 lb CF8M | −30 to 65 °C | 16.3 bar |
| 65 to 250 °C | ↘ Fig. 4 | |
| Flanges ANSI B16.5 · 300 lb WCB | −30 to 65 °C | 51 bar |
| 65 to 260 °C | ↘ Fig. 4 | |
| Flanges ANSI B16.5 · 300 lb CF8M | −30 to 65 °C | 42.5 bar |
| 250 °C | 30 bar |
Limits from manual MTEC-03/00 (Figures 1 to 4) by material and flange class. At ↘, pressure decreases with temperature: read the value on the figure curve. The allowable pressure is limited by the lowest-rated component and the sealing configuration.
Pump cross-section, design features and sealing chamber arrangements as given in manual MTEC-03/00.
Lubrication by pumped fluid / internal sealing. For clean, non-aggressive fluids. Up to 160 °C.
Sealing by external clean liquid. For toxic, aggressive, foul-smelling fluids or vacuum suction. Up to 105 °C.
External lubrication and sealing. For fluids with solid particles or fibers in suspension. Up to 105 °C.
Flushing with external clean liquid. For fluids with abrasives or crystallization risk. Up to 105 °C.
Pure graphite and/or graphite with carbon fiber packing. No connections. Above 260 °C.
Per application requirements and manufacturer consultation.
(*) External source applications cannot use a cooling chamber. The arrangement temperatures are those in section 10 of the manual; in Table 1, with packing and without a cooling chamber, the range is −50 to 105 °C.
Provide the equipment identification and, if available, the part reference in the drawing. Include the fluid and operating temperature to discuss the configuration. This model reference is carried into the form.
| Connection | Function | Size · NPT thread |
|---|---|---|
| D1 | Pump drain | 3/8 |
| D2 | Bearing frame drain | 1/4 |
| D3 | Bearing frame drip | 1/2 |
| D4 | Baseplate drain | 1 |
| L1 | Lubrication | Ø20 mm |
| M1 | Pressure gauge | 1/4 |
| M2 | Compound gauge | 1/4 |
| Re | Cooling inlet | 1/2 |
| Rs | Cooling outlet | 1/2 |
| Se | Sealing inlet | 1/2 |
| Ss | Sealing outlet | 1/2 |
“R” recirculation hole for the pumped fluid: Rp1/8" thread.
| No. | Part | Qty. |
|---|---|---|
| 102 | Casing – volute body | 1 |
| 163 | Pressure cover | 1 |
| 165 | Cooling chamber coverOnly on pumps with a cooling chamber. | 1 |
| 183 | Support foot | 1 |
| 210 | Shaft | 1 |
| 230 | Impeller | 1 |
| 321 | Radial ball bearing | 2 |
| 330 | Bearing frame | 1 |
| 360 | Bearing cover | 2 |
| 400.1 | Flat gasket – casing / pressure cover | 1 |
| 400.2 | Flat gasket – bearing cover / frame | 2 |
| 400.3 | Flat gasket – impeller / impeller screw | 1 |
| 400.4 | Flat gasket – shaft sleeve / impeller | 1 |
| 400.5 | Flat gasket – pressure cover / gland plate | 1 |
| 412.1 | O-ring – cooling cover / pressure cover | 1 |
| 412.2 | O-ring – cooling cover / pressure cover | 1 |
| 421 | Lip seal | 2 |
| 433 | Mechanical sealNot applicable to packed pumps. | 1 |
| 452 | Gland followerNot applicable to pumps with a mechanical seal. | 1 |
| 456 | Throat bushingWhen the pumped fluid is thermal oil (section 10). | 1 |
| 457 | Throat ringIf required, for stuffing box flushing (section 10). | 1 |
| 458 | Lantern ringNot applicable to pumps with a mechanical seal. | 1 |
| 461 | Packing ringNot applicable to pumps with a mechanical seal. | Varies by pump |
| 471 | Gland plateNot applicable to packed pumps. | 1 |
| 502 | Casing wear ring | 1 |
| 503 | Impeller wear ring | 1 |
| 507 | Flinger ringNot applicable to pumps with a mechanical seal. | 1 |
| 524 | Shaft sleeve | 1 |
| 554.1 | Washer – pressure cover / casing | Varies by pump |
| 639 | Oil level indicator | 1 |
| 901.1 | Hex head bolt – pressure cover / casing | Varies by pump |
| 901.2 | Hex head bolt – frame / casing or pressure cover | Varies by pump |
| 901.3 | Hex head bolt – bearing cover / frame | 8 |
| 901.4 | Hex head bolt – support foot / frame | 1 |
| 902 | Stud – pressure cover / gland follower or gland plateThe manual prints “2 or” without completing the quantity. | — |
| 903.1 | Plug – discharge flange | 2 |
| 903.2 | Plug – suction flange | 2 |
| 903.3 | Plug – pump drain | 1 |
| 903.4 | Plug – bearing frame drain | 1 |
| 903.5 | Plug – recirculation, cooling or sealing connectionsAccording to the sealing chamber arrangement (section 10). | 2 |
| 906 | Impeller screw | 1 |
| 920.1 | Nut – gland follower or gland plateThe manual prints “2 or” without completing the quantity. | — |
| 932 | Retaining ring | 1 |
| 940.1 | Key | 1 |
| 940.2 | Key | 1 |
| 970 | Nameplate | 1 |
Numbering per DIN EN 24250. When ordering parts, state the pump size and the part number.
Impeller peripheral speed, efficiency reduction for stainless impellers, motor power reserve and set accessories.
| Impeller material | Maximum speed |
|---|---|
| Cast iron | ≤ 40 m/s |
| Ductile iron | ≤ 60 m/s |
| Carbon steel | ≤ 60 m/s |
| Stainless steel | ≤ 80 m/s |
| Impeller passage width | Efficiency reduction |
|---|---|
| up to 12 mm | 3 points |
| from 12 to 15 mm | 2 points |
| above 15 mm | no reduction |
For a stainless steel impeller, the efficiency shown on the characteristic curves must be reduced according to this table.
Impeller width · FBCN 80-200 (Table 1 (p. 5)): 23 mm
| Pump power requirement | Motor reserve |
|---|---|
| up to 2 cv | approx. 20% (minimum 1.5 cv) |
| up to 20 cv | approx. 15% |
| above 20 cv | approx. 10% |
MTEC-03/00 · PDF · 460 KB · Portuguese
FBCN curve catalog at 1750 rpm · PDF · p. 27 · Portuguese
FBCN curve catalog at 3500 rpm · PDF · p. 24 · Portuguese
FBCN 80-200 has DN125 suction and DN80 discharge, approximate weight 92 kg in cast iron and 95 kg in steel. Total length 500 mm, total height 250 mm, foot width 65 mm. Dimensions extracted from FBCN technical manual page 14.
FBCN 80-200 uses bearing frame 40, with C3-clearance radial ball bearings. The sealing chamber has 3/8" packing, chamber Ø64 mm with sleeve Ø45 mm and length 71 mm. Sealing is by packing or mechanical seal. Data from Table 1 of technical manual MTEC-03/00, page 5.
The FBCN series handles clean or turbid liquids in applications including Chemical industry, Petrochemical industry, Pulp and paper industry, Steelmaking industry. For FBCN 80-200, DN125 suction and DN80 discharge must be assessed together with the model curve. FB Bombas application engineering validates the operating point per characteristic curve and system NPSH available before final specification.
The FBCN Technical Manual MTEC-03/00 describes mechanical construction per ASME B73.1 and a back pull-out arrangement. Confirm the configuration, materials and documents required by your project in the quotation.
Share the installation conditions to assess this model and prepare your quotation. The form carries the selected pump reference.
Models with the same and adjacent discharge sizes, for reference. Check each model’s dimensions, curves and installation conditions; these groups do not establish hydraulic equivalence.