I have a series or model
Review the equipment, dimensions and family documentation. For replacement, also provide the identification of your existing pump.
View the catalog
Direct service from our factory in Cabreúva, Brazil. Explore FB Bombas series and tell us what your operation needs to transfer or circulate.
Do you already know the pump or need help defining it? Choose the next step for your industrial project.
Review the equipment, dimensions and family documentation. For replacement, also provide the identification of your existing pump.
View the catalogTell us which fluid you need to transfer or circulate and how the pump will be used. You can start the conversation without all the technical details.
Describe my applicationSelection depends on the fluid and operating conditions. Location identifies the project and delivery destination.

Standardized centrifugal pumps for industrial processes. Compare curves, nozzles and dimensions to select a model.
Explore models
Horizontal construction with multiple stages for pressure elevation. Consult curves, sizes and technical documentation.
Explore models
Pumps for thermal oil circulation in industrial heating systems. Consult the series operating conditions.
Explore modelsApplication context and points to confirm during technical and commercial review.
For projects in Rio dos Cedros, Santa Catarina, FB Bombas provides service from its factory in Cabreúva, Brazil. Review FBCN for industrial processes, FBME for multistage configurations and FBOT for thermal oil circulation. Selection depends on fluid, flow, head and installation conditions. Check the model curve and documentation with the team.
Describe your plant activity and the pump’s role in the process: transfer, circulation or feed. The team combines this information with fluid and installation data to guide the review of product families.
For industrial projects in Rio dos Cedros, FB Bombas provides direct service from its factory in Cabreúva, Brazil. A pump manufacturer since 1944, the company reviews the process, fluid and installation conditions with your team to define the equipment.
State whether the requirement is an expansion, new installation or equipment replacement. For replacement, pump identification and its dimensional drawing help check the duty point and existing interfaces.
For centrifugal pumps in Rio dos Cedros, check the model curve at the proposed speed and impeller diameter. Flow and head duty, suction conditions, fluid and installation interfaces need to be reviewed together before confirming the equipment.
The project location in Rio dos Cedros does not determine the pump series. Compare families by fluid and process, then confirm selection using flow, pressure or head, temperature, viscosity and installation conditions.
Support for Rio dos Cedros starts through the factory channels in Cabreúva, Brazil. Have the equipment identification and a description of operating conditions ready to support maintenance, spare-parts or replacement review.
For economic context, IBGE records GDP of R$ 566 million for Rio dos Cedros in 2023. In the 2021 gross value added breakdown, industry accounts for approximately 35.7% and agriculture for approximately 9.2%. Reference years differ because the 2022–2023 publication does not include a sector breakdown. These data describe the municipality; pumping requirements need to be specified for your plant’s process.
To organize supply for Rio dos Cedros, state the number of pumps and each assembly’s role in the plant. Identify the duty points and operating schedule of each circuit, including the intended conditions for standby equipment.
To describe the industrial application in Rio dos Cedros, identify the process stage and whether the pump will transfer, circulate or feed another item of equipment. The same plant may have circuits with different fluid, flow, pressure and duty requirements.
If the operation in Rio dos Cedros uses different fluids, record composition, viscosity, temperature and solids content separately for each circuit. Compatibility with one product does not establish that the pump will serve every other plant process.
Source: IBGE — Municipal GDP and methodologyAbout 440 km in a straight line between the factory in Cabreúva, São Paulo, and the geographic center of the municipality (IBGE centroid). It is not a road route, freight cost or lead time.
Haversine formula, treating the Earth as a sphere with a radius of 6,371 km, between the factory’s reference coordinates (Av. Adolpho João Traldi, 80 - Jacaré, Cabreúva-SP) and the municipal centroid published by IBGE in its Geographic Mesh API, retrieved on September 24, 2026. The centroid is a reference point of the municipal territory, not the municipal seat or the delivery location. The result is rounded to multiples of 5 km; below 20 km, only “less than 20 km” is shown.
IBGE Mesh API documentationThe project destination in Rio dos Cedros should be included in the quotation with the delivery address and access conditions. Route and transit time are confirmed for the cargo and selected carrier; distance between cities does not replace that planning.
Service for Rio dos Cedros starts through the factory channels in Cabreúva, Brazil. Describe the need and equipment. Site visits, commissioning or field service depend on scope review, scheduling and commercial conditions.
To review the FBCN / FBME / FBOT families for the project in Rio dos Cedros, send the fluid and any known flow, pressure or head and temperature data. For replacement, add the installed pump’s identification and drawing. The team confirms the configuration and proposal scope.
Review process criteria and prepare the information for equipment selection.
Centrifugal pump selection for raw water intake, treated water pumping, boosters, lift stations and water and wastewater treatment processes: fluid and solids, materials, sealing arrangements, NPSH and the documented limits of the FBCN line — and where the right technology is a different one.
View applicationPump selection for acids, caustic bases, organic solvents, polymers, intermediates and pharmaceutical plant utilities — criteria for material, sealing, classified areas and the boundary between chemical service and sanitary product contact.
View applicationChilled water, condenser water, transfer and boosting have different demands. Organise thermal load, flow, head, water quality and controls to assess FBCN against actual building conditions.
View applicationHow to select the boiler feed water pump (feed and condensate return) and the hot water pump for cooling towers, building HVAC, sanitary hot water and solar heating: the three limits that must be checked separately — the pump, the sealing and the system NPSH — and what the FBCN and FBME series manuals document for each.
View applicationShare what you already know. Additional details can be clarified with the team during review.
What needs to be pumped, where it comes from and where it needs to go.
Flow, pressure or head, temperature and operating schedule, when known.
Series, model, identification and space or connection constraints, if a pump is already installed.
Project location, requested scope and documents required for your purchase.

FB Bombas is a Brazilian manufacturer with a history dating back to 1944. Our factory in Cabreúva, São Paulo, brings together CNC machining, assembly and a hydraulic test bench. The team reviews your application and confirms the configuration, documents and supply conditions in the proposal.
About FB BombasUse the family documentation and application guides to prepare your request.
Installation, operation and maintenance by series, with the document language identified.
Understand the process information needed to specify the equipment.
View applicationsSee the other pages for this city and for other cities. Service is provided by the factory in Cabreúva, Brazil.
Information to help you prepare your inquiry to FB Bombas.
The published grade is for the FBME: service manual MSERV-08/01 (item 12.2) specifies static and dynamic impeller balancing to grade G6.3. The manuals of the other series do not publish a grade; for them and for critical projects in Rio dos Cedros, specify the required standard, grade and report in the purchase scope. Impeller balancing alone does not guarantee the vibration level of the installation.
FB Bombas serves projects in Rio dos Cedros from its Cabreúva-SP factory, with direct engineering support and parts supply for its equipment. Availability, lead time, transport and on-site service are assessed according to the request. Its industrial pump manufacturing history began in 1944.
Yes. Projects in Rio dos Cedros are handled by the factory team in Cabreúva, Brazil. Send your industrial requirement and the data already available. Configuration, availability, transport and any on-site service are confirmed according to the requested scope.
Send the series and model of the pump installed in Rio dos Cedros, the operating conditions and the available vibration records; the standard, measurement points and limits are defined for the assembly, with no single limit for every pump. Check the alignment first: the FBEI (MAN001-10) and FBME (MSERV-08/01) manuals identify pump-to-motor misalignment as a source of vibration and premature wear and call for realignment after final installation, because transport usually misaligns the set, which leaves the factory pre-aligned; the stated tolerance is under 0.05 mm radial and 0.6° angular, according to the coupling supplier.
It depends on the model and the duty point; there is no single efficiency figure for the brand. The FBCN and FBME characteristic curves show the efficiency of each model and, for stainless-steel impellers with passages up to 15 mm, the FBCN manual deducts 2 or 3 points from the curve efficiency (Table 4). For the project in Rio dos Cedros, compare the absorbed power at the process flow, head and fluid, also considering drive, control and operating duty.
It depends on the series. The catalogue for the FBE external gear pump lists oils in general, greases, asphalt, diesel oil, kerosene, paints, varnishes, resins and solvents, as well as lubrication systems and hydraulic equipment. The FBEI internal gear pump is intended for high-viscosity liquids. The FBCN and FBME handle clean or turbid liquids, and the FBOT handles organic thermal oils free of abrasive particles and of substances that chemically attack the pump. For the process in Rio dos Cedros, state the composition, temperature, viscosity and solids content; fluids with suspended solids must be assessed by FB engineering.
The catalogue includes FBE external gear, FBEI internal gear, FBCN standardized centrifugal, FBME multistage centrifugal and FBOT thermal oil pumps, fire systems and custom solutions. Review each family’s documentation; configuration and availability are confirmed in the quotation.
It depends on the series. On the FBCN and FBOT, back pull-out construction allows the bearing-housing assembly to be removed without disconnecting the piping, and the FBEI catalogue also indicates back pull-out construction. The FBE external gear pump is not back pull-out: its shafts are supported on bushings. Before working on the equipment in Rio dos Cedros, check the series manual, the sectional drawing and the parts list.
Use the website form, WhatsApp +55 11 97287-4837 or comercial@fbbombas.com.br. Describe the project in Rio dos Cedros, fluid and technical data you already have. The team reviews the application, clarifies missing information and confirms the configuration and proposal conditions.
It can, especially with viscous fluids. On the FBE, speed and transmission are set by fluid viscosity (Table 2 of manual MTEC-01/01), and the heating chamber is available only on sizes from 1.1/2" to 6". The FBEI manual requires the fluid to be at the proper temperature and viscosity before start-up and the heating jacket to be supplied gradually, with steam up to 185 °C or thermal fluid up to 232 °C, both up to 10 bar. State the minimum site temperatures and the fluid viscosity at start-up and in operation in Rio dos Cedros.
Send your application to our factory team. You do not need every parameter defined to start the conversation.
The team reviews the information and confirms the details needed for a proposal. Configuration, availability, documentation, transport and lead time depend on the requested scope.
Describe the fluid, application and project destination. Include the model and technical data you already have.