I have a series or model
Review the equipment, dimensions and family documentation. For replacement, also provide the identification of your existing pump.
View the catalog
Direct service from our factory in Cabreúva, Brazil. Explore FB Bombas series and tell us what your operation needs to transfer or circulate.
Do you already know the pump or need help defining it? Choose the next step for your industrial project.
Review the equipment, dimensions and family documentation. For replacement, also provide the identification of your existing pump.
View the catalogTell us which fluid you need to transfer or circulate and how the pump will be used. You can start the conversation without all the technical details.
Describe my applicationSelection depends on the fluid and operating conditions. Location identifies the project and delivery destination.

Standardized centrifugal pumps for industrial processes. Compare curves, nozzles and dimensions to select a model.
Explore models
Horizontal construction with multiple stages for pressure elevation. Consult curves, sizes and technical documentation.
Explore models
Pumps for thermal oil circulation in industrial heating systems. Consult the series operating conditions.
Explore modelsApplication context and points to confirm during technical and commercial review.
For projects in Boa Vista, Roraima, FB Bombas provides service from its factory in Cabreúva, Brazil. Review FBCN for industrial processes, FBME for multistage configurations and FBOT for thermal oil circulation. Selection depends on fluid, flow, head and installation conditions. Check the model curve and documentation with the team.
Describe your plant activity and the pump’s role in the process: transfer, circulation or feed. The team combines this information with fluid and installation data to guide the review of product families.
For industrial projects in Boa Vista, FB Bombas provides direct service from its factory in Cabreúva, Brazil. A pump manufacturer since 1944, the company reviews the process, fluid and installation conditions with your team to define the equipment.
Delivery planning for Boa Vista needs the full address and plant access restrictions. Surrounding roads help locate the project, but the cargo route, carrier and timing must be confirmed when contracting transport.
State whether the requirement is an expansion, new installation or equipment replacement. For replacement, pump identification and its dimensional drawing help check the duty point and existing interfaces.
For centrifugal pumps in Boa Vista, check the model curve at the proposed speed and impeller diameter. Flow and head duty, suction conditions, fluid and installation interfaces need to be reviewed together before confirming the equipment.
To define materials for the project in Boa Vista, provide fluid composition, concentration, temperature and solids content. Also describe the external environment; the city name does not establish chemical compatibility or determine pump material.
The project location in Boa Vista does not determine the pump series. Compare families by fluid and process, then confirm selection using flow, pressure or head, temperature, viscosity and installation conditions.
Support for Boa Vista starts through the factory channels in Cabreúva, Brazil. Have the equipment identification and a description of operating conditions ready to support maintenance, spare-parts or replacement review.
For economic context, IBGE records GDP of R$ 18.2 billion for Boa Vista in 2023. In the 2021 gross value added breakdown, industry accounts for approximately 11% and agriculture for approximately 1.6%. Reference years differ because the 2022–2023 publication does not include a sector breakdown. These data describe the municipality; pumping requirements need to be specified for your plant’s process.
To organize supply for Boa Vista, state the number of pumps and each assembly’s role in the plant. Identify the duty points and operating schedule of each circuit, including the intended conditions for standby equipment.
To describe the industrial application in Boa Vista, identify the process stage and whether the pump will transfer, circulate or feed another item of equipment. The same plant may have circuits with different fluid, flow, pressure and duty requirements.
If the operation in Boa Vista uses different fluids, record composition, viscosity, temperature and solids content separately for each circuit. Compatibility with one product does not establish that the pump will serve every other plant process.
Source: IBGE — Municipal GDP and methodologyAbout 3,285 km in a straight line between the factory in Cabreúva, São Paulo, and the geographic center of the municipality (IBGE centroid). It is not a road route, freight cost or lead time.
Haversine formula, treating the Earth as a sphere with a radius of 6,371 km, between the factory’s reference coordinates (Av. Adolpho João Traldi, 80 - Jacaré, Cabreúva-SP) and the municipal centroid published by IBGE in its Geographic Mesh API, retrieved on September 24, 2026. The centroid is a reference point of the municipal territory, not the municipal seat or the delivery location. The result is rounded to multiples of 5 km; below 20 km, only “less than 20 km” is shown.
IBGE Mesh API documentationThe project destination in Boa Vista should be included in the quotation with the delivery address and access conditions. Route and transit time are confirmed for the cargo and selected carrier; distance between cities does not replace that planning.
Service for Boa Vista starts through the factory channels in Cabreúva, Brazil. Describe the need and equipment. Site visits, commissioning or field service depend on scope review, scheduling and commercial conditions.
To review the FBCN / FBME / FBOT families for the project in Boa Vista, send the fluid and any known flow, pressure or head and temperature data. For replacement, add the installed pump’s identification and drawing. The team confirms the configuration and proposal scope.
Review process criteria and prepare the information for equipment selection.
Centrifugal pump selection for raw water intake, treated water pumping, boosters, lift stations and water and wastewater treatment processes: fluid and solids, materials, sealing arrangements, NPSH and the documented limits of the FBCN line — and where the right technology is a different one.
View applicationPump selection for acids, caustic bases, organic solvents, polymers, intermediates and pharmaceutical plant utilities — criteria for material, sealing, classified areas and the boundary between chemical service and sanitary product contact.
View applicationChilled water, condenser water, transfer and boosting have different demands. Organise thermal load, flow, head, water quality and controls to assess FBCN against actual building conditions.
View applicationHow to select the boiler feed water pump (feed and condensate return) and the hot water pump for cooling towers, building HVAC, sanitary hot water and solar heating: the three limits that must be checked separately — the pump, the sealing and the system NPSH — and what the FBCN and FBME series manuals document for each.
View applicationShare what you already know. Additional details can be clarified with the team during review.
What needs to be pumped, where it comes from and where it needs to go.
Flow, pressure or head, temperature and operating schedule, when known.
Series, model, identification and space or connection constraints, if a pump is already installed.
Project location, requested scope and documents required for your purchase.

FB Bombas is a Brazilian manufacturer with a history dating back to 1944. Our factory in Cabreúva, São Paulo, brings together CNC machining, assembly and a hydraulic test bench. The team reviews your application and confirms the configuration, documents and supply conditions in the proposal.
About FB BombasUse the family documentation and application guides to prepare your request.
Installation, operation and maintenance by series, with the document language identified.
Understand the process information needed to specify the equipment.
View applicationsSee the other pages for this city and for other cities. Service is provided by the factory in Cabreúva, Brazil.
Information to help you prepare your inquiry to FB Bombas.
The proposal should define availability, dispatch, transport, packaging and responsibilities for delivery to Boa Vista. State access, unloading and receiving restrictions. Route, mode and timing are confirmed for the supply; a reference distance is not a road route or delivery time.
It depends on the series. The published limits are up to 260 °C for the FBCN, 350 °C for the FBOT, 340 °C for the FBEI and 140 °C for the FBME. For the FBE, the 2026 catalogue gives a range of 10 °C to 500 °C; the limit of each configuration depends on materials and sealing. These are series limits: they do not automatically apply to every model, nor do they necessarily occur together with the other maximums. State the start-up, operating and cleaning temperatures of the process in Boa Vista.
Following the BNDES steps, first check whether the equipment appears on the list of items eligible for BNDES Finame financing, in the CFI Catalog on the bank’s website; for that check, ask the sales team for the identification of the model quoted for Boa Vista. Then apply for financing through an accredited financial agent, such as a commercial bank, development bank, development agency or credit union. The agent reviews the request and, if it approves the operation, forwards it to BNDES, which evaluates the request and authorizes the financing. Being a Brazilian manufacturer does not, on its own, show that the equipment is accredited.
Send the application in Boa Vista, fluid, temperature and available flow, pressure or head data. For replacement, add the equipment model, identification and drawing. Also state the destination and purchase documentation requirements. The team confirms any additional data needed and the technical and commercial proposal scope.
Service can be requested for Boa Vista and other destinations through the factory channels in Cabreúva, Brazil. Provide each project location and required scope to confirm supply and transport conditions. This does not represent a physical FB Bombas location in every city.
Use the website form, WhatsApp +55 11 97287-4837 or comercial@fbbombas.com.br. Describe the project in Boa Vista, fluid and technical data you already have. The team reviews the application, clarifies missing information and confirms the configuration and proposal conditions.
Yes, in the five Custom Solutions categories: custom complete motor-pump assembly, mobile industrial kit, industrial pump skid, retrofit with a new FB pump in place of the installed one, and special materials projects. The scope of each project is defined with engineering before manufacture in Cabreúva, Brazil.
Yes, for FB product lines. The FBE catalogue lists replacement components such as shafts, gears, bushing sets, covers, mechanical seal, lip seal and relief valve, and the FBEI and FBME manuals include spare-parts lists for two years of operation. For delivery to Boa Vista, state the series, model, manufacturing number and component; compatibility, availability and lead time are confirmed in the quotation. Supply ships from the factory in Cabreúva, Brazil; the city page does not indicate local stock. Use original parts: the FBME service manual makes the operating and performance warranty conditional on original parts and FB’s consent.
FB Bombas reports a registration in the Petrobras supplier registry (CRC, formerly CRCC). It is a supplier registration, not a product certification; validity and supply families appear on the current certificate, provided on request. Technical standards depend on the series: mechanical construction per ASME B73.1 for the FBCN, NFPA 20 or ABNT NBR 16704 for FBFS fire pump sets when the project requires it, and API 610 for engineered-to-order projects. These bodies publish standards; they do not certify the company. Tests and certificates for each supply are defined in the proposal.
Warranty conditions are defined in the proposal and contract and vary with the series, operating conditions and agreement. The manuals state what can void it. Under the FBEI manual (MAN001-10), operating with a different fluid or outside the pump’s data sheets and certified documents without FB’s written authorization voids the warranty. Under the FBME service manual (MSERV-08/01), after parts are replaced, the operating and performance warranty applies only with original parts and FB’s consent. For the project in Boa Vista, confirm the conditions in the quotation.
Send your application to our factory team. You do not need every parameter defined to start the conversation.
The team reviews the information and confirms the details needed for a proposal. Configuration, availability, documentation, transport and lead time depend on the requested scope.
Describe the fluid, application and project destination. Include the model and technical data you already have.