Skip to main content

Request your Quote for NFPA 20 Fire Pump Skid

Brazilian industrial pump manufacturer since 1944. Complete skids designed to NFPA 20 or ABNT NBR 16704, with centrifugal main pump, jockey and diesel or electric drive. Direct engineering quote based on the project scope.

The applicable standard and conformity documentation are defined for each project.

How it works

3 simple steps for your quote

  1. Submit Your Request

    Fill out the form with your application data: fluid, flow, pressure and working temperature.

  2. Technical Sizing

    Our engineering team analyzes your demand and selects the ideal pump for your application.

  3. Receive Your Quote

    After engineering analysis you receive a detailed commercial proposal with technical specifications.

What to provide

  • Occupancy or protected hazard and system served (sprinklers or hydrants)
  • Design flow and pressure defined by the fire protection designer
  • Driver: electric, diesel or combined
  • Standards and local requirements specified for the project
  • Scope: main pump, jockey, control panel and assembly

Partial data is enough to get started. Nameplate photos, drawings or data sheets can be sent via WhatsApp.

Request your Fire Pump Skid Quote

Fill out the form and engineering replies after reviewing your request.

Include the area code. No need to repeat +55.

Reply after we review your request

or

Talk now on WhatsApp

How much does a fire pump system cost?

Fire-fighting systems designed to NFPA 20 or ABNT NBR 16704 have no public list price: the value is defined by the project hydraulic demand (sprinkler or hydrant flow × pressure), the driver type (electric, diesel or redundant) and the package scope — main pump, jockey, panel, piped skid or pump house. FB Bombas manufactures complete FBFS packages and quotes per project, factory-direct from Cabreúva-SP, with the package technical documentation for review by the insurer and the Fire Department.

What drives the price of a fire pump system

  • Design flow and pressure

    The hydraulic demand of the hazard, defined in the system design (for example, automatic sprinklers under ABNT NBR 10897 or hydrants under ABNT NBR 13714), sizes the main pump and driver — the starting point of the value.

  • Driver type

    Electric (TEFC/TEAAC motor), diesel, or electric + diesel redundancy for critical systems — the diesel package adds a fire-service engine, batteries, fuel tank and dedicated panel; whether a listed engine is required follows the project standard.

  • Package scope

    Standard package (main pump + jockey + panel), complete piped skid or prefabricated pump house — each step extends the supply.

  • Panel and starting method

    Control panel and direct, soft or VFD starting (on request), defined by the project standard and ABNT NBR 5410. If the project or the insurer requires a panel listed for fire pump service (UL/FM), state it in the specification: FB Bombas does not supply UL/FM-listed packages.

  • Tests and documentation

    When the project follows NFPA 20, the test curve records 0%, 100% and 150% of rated flow; documented FAT and a package technical dossier for the insurer and the Fire Department, as set in the proposal.

There is no public list price for systems designed to NFPA 20 or ABNT NBR 16704 — the market quotes per project. At FB Bombas, the package is sized by engineering from the hydraulic demand of the hazard, and the quotation comes with detailed scope (main pump, jockey, panel, driver), test curve, lead time and written conditions.

What defines the price of an NFPA 20 fire-fighting system?

Three blocks define the value: (1) the project hydraulic demand — flow and pressure required by sprinklers (ABNT NBR 10897) or hydrants (ABNT NBR 13714), which size pump and driver; (2) the driver — electric, diesel or electric + diesel redundancy; (3) the scope — standard package with jockey and panel, complete piped skid or prefabricated pump house. Tests under the standard adopted by the project (NFPA 20 or ABNT NBR 16704) and insurer documentation complete the supply.

Does a diesel system cost more than an electric one?

Generally yes: the diesel package includes a fire-service engine, batteries with charger, fuel tank and a dedicated control panel — components the equivalent electric package does not require. Diesel is specified when electric power is not assured in the fire scenario; critical systems (data centers, port terminals) may adopt electric + diesel redundancy. The choice comes from the project, not from a catalog.

Can I buy the fire pump system directly from the manufacturer?

Yes. FB Bombas manufactures FBFS packages in Cabreúva-SP and sells factory-direct: main pump, jockey and panel sized by engineering, designed to NFPA 20 or ABNT NBR 16704 as the project requires, with documented FAT, test curve and commissioning support defined in the proposal. Send your project hydraulic demand through the form on this page to receive the proposal.

Buy factory-direct

  • Application engineering in the specification

    Fluid, viscosity, flow, pressure and available NPSH analyzed by the people who build the pump — model and sealing selection comes from engineering, before the proposal.

  • Manufacturer warranty

    The warranty is issued by the manufacturer itself: term, coverage and exclusions are defined in writing in the commercial proposal, according to the series and operating conditions.

  • Genuine parts and direct after-sales

    Genuine spare parts (impellers, gears, shafts, bushings, seals, bearings, depending on the series) and after-sales technical support come from the same factory; availability and lead time are confirmed at quotation.

  • Factory lead time confirmed in writing

    The manufacturing order opens at the plant itself and the lead time is documented in the technical-commercial proposal, along with performance curve and conditions.

Brazilian industrial pump manufacturer since 1944 — factory in Cabreúva-SP.

Frequently asked questions

Quote inquiries

How long to receive a quote?

Our technical team replies after reviewing your request. Timing depends on the sizing scope.

What information do I need to provide?

For accurate sizing, provide: fluid type, desired flow (L/min or m³/h), working pressure (bar or psi), operating temperature, and fluid viscosity if available.

Does FB Bombas manufacture custom pumps?

Yes. In addition to standard FBE, FBCN and FBOT lines, we manufacture pumps with custom specifications for special applications. Consult our technical team.

Do you serve all of Brazil?

Yes. We serve all of Brazil from our factory in Cabreúva/SP and answer project inquiries from Latin America; freight, destination and shipping documents are defined in the proposal.

Is it possible to visit the factory?

Yes, we receive technical visits by prior appointment. Our factory is at Av. Adolpho João Traldi, 80, Cabreúva/SP. Schedule by phone +55 11 4898-9200.

What payment methods are accepted?

Payment methods and terms are defined in the commercial proposal, after registration and credit review. If your purchasing process requires a specific method, state it in the request.