FBOT50-200
Thermal oil centrifugal pump — suction DN80mm, discharge DN50mm, back-pull-out construction.
Operational Limits
Data from Table 1 and Figure 1 of the technical manual
Maximum discharge pressure × temperature (manual Figure 1)
Maximum discharge pressure as a function of temperature. Approximate values from Figure 1 of the technical manual. For critical applications, consult FB Bombas engineering.
Technical Dimensions
Dimensions in millimeters per Table 5 of the FBOT Technical Manual
| Dimension | Value (mm) |
|---|---|
| DN1 — Suction | 80 |
| DN2 — Discharge | 50 |
| a | 100 |
| f | 360 |
| h1 | 160 |
| h2 | 200 |
| b | 50 |
| g1 | 15 |
| g2 | 6,35 |
| l1 | 30 |
| m1 | 100 |
| m2 | 70 |
| m3 | 65 |
| n1 | 265 |
| n2 | 212 |
| n3 | 160 |
| n4 | 110 |
| s1 | 14 |
| s2 | 14 |
| V | 100 |
| W | 260 |
| d1 m6 (eixo) | 24 |
| l | 50 |
| t | 26,9 |
| u | 8 |
| x | 100 |
Source: Table 5 of the official FBOT Technical Manual — all dimensions in millimeters.
Construction & Components
Official construction data from the technical manual
Back-Pull-Out Construction
Back-pull-out construction — allows bearing frame removal without disconnecting/misaligning piping. Simplifies maintenance.
Pump Body
Spiral-shaped body, cast in single piece without feet.
Impeller
Closed radial impeller, single suction.
Dual Sealing System
Dual safety sealing — graphite packing in first stage (in contact with thermal oil) + oil-submerged mechanical seal inside the bearing frame (ensures thermal stability).
Bearing Frame — Bearing frame 3 — 6306 bearings
Auxiliary Connections
- D1 — Support drain (¼" BSP)
- D2 — Mechanical seal leakage indicator (¼" BSP)
- FF — Oil supply (¼" BSP)
- V — Vent (¼" BSP)
Standard model — default FBOT configuration
This model follows the standard FBOT series construction: single-piece cast spiral body, closed radial single-suction impeller and dual sealing (packing + oil-submerged mechanical seal). Indicated for most thermal oil applications where discharge pressure follows the standard curve of manual Figure 1 (up to 16 bar at 100°C, decreasing to 10 bar at 350°C).
Frequently Asked Questions
Model-specific technical answers based on the official manual
Application-Specific Sizing
Specific flow rate, head and power depend on the thermal oil, temperature, density, viscosity and available NPSH. Our engineering sizes the ideal FBOT pump using characteristic curves from the technical manual — response within 48 business hours.
All dimensions and construction information were extracted from the official FB Bombas FBOT Technical Manual (MTEC-16/00). Application-specific performance must be consulted with the Engineering Department.