I have a series or model
Review the equipment, dimensions and family documentation. For replacement, also provide the identification of your existing pump.
View the catalog
Direct service from our factory in Cabreúva, Brazil. Explore FB Bombas series and tell us what your operation needs to transfer or circulate.
Do you already know the pump or need help defining it? Choose the next step for your industrial project.
Review the equipment, dimensions and family documentation. For replacement, also provide the identification of your existing pump.
View the catalogTell us which fluid you need to transfer or circulate and how the pump will be used. You can start the conversation without all the technical details.
Describe my applicationSelection depends on the fluid and operating conditions. Location identifies the project and delivery destination.

External gear pumps for viscous fluid transfer. Check size-specific limits and availability with our sales team.
Explore models
Internal gear pumps for viscous fluid transfer. Review the configuration, materials and series documentation.
Explore modelsApplication context and points to confirm during technical and commercial review.
For projects in São Caetano do Sul, São Paulo, FB Bombas provides service from its factory in Cabreúva, Brazil. FBE external gear pumps and FBEI internal gear pumps have their own documentation and operating conditions. Provide the fluid, viscosity at operating temperature and any known flow and pressure data. The team reviews the appropriate configuration.
Identify the fluid by its trade name and available composition. Add viscosity at operating temperature, solids content and startup conditions. These data allow materials and sealing to be assessed before the configuration is confirmed.
For industrial projects in São Caetano do Sul, FB Bombas provides direct service from its factory in Cabreúva, Brazil. A pump manufacturer since 1944, the company reviews the process, fluid and installation conditions with your team to define the equipment.
Describe your plant activity and the pump’s role in the process: transfer, circulation or feed. The team combines this information with fluid and installation data to guide the review of product families.
State whether the requirement is an expansion, new installation or equipment replacement. For replacement, pump identification and its dimensional drawing help check the duty point and existing interfaces.
For gear pumps in São Caetano do Sul, review FBE external gear pumps and FBEI internal gear pumps separately. Their models, drives and limits are not interchangeable; provide viscosity at startup and operating temperatures to assess the configuration.
The project location in São Caetano do Sul does not determine the pump series. Compare families by fluid and process, then confirm selection using flow, pressure or head, temperature, viscosity and installation conditions.
For the project in São Caetano do Sul, record the required duty point and process variation range. Catalogue maxima do not mean that maximum flow, pressure and temperature can occur together on any model; check the documentation for the proposed configuration.
If the project in São Caetano do Sul requires testing or witnessed inspection, specify test points, acceptance criteria and required reports in the purchase requirements. The team confirms capability and scope before supply, according to the series and configuration.
For economic context, IBGE records GDP of R$ 22.6 billion for São Caetano do Sul in 2023. In the 2021 gross value added breakdown, industry accounts for approximately 26.6% and agriculture for less than 0.1%. Reference years differ because the 2022–2023 publication does not include a sector breakdown. These data describe the municipality; pumping requirements need to be specified for your plant’s process.
For fluids with varying properties in the process in São Caetano do Sul, provide composition, temperature and viscosity ranges plus startup and cleaning conditions. Identify each product that will pass through the assembly to guide the review of materials, sealing and drive.
If the operation in São Caetano do Sul uses different fluids, record composition, viscosity, temperature and solids content separately for each circuit. Compatibility with one product does not establish that the pump will serve every other plant process.
To describe the industrial application in São Caetano do Sul, identify the process stage and whether the pump will transfer, circulate or feed another item of equipment. The same plant may have circuits with different fluid, flow, pressure and duty requirements.
Source: IBGE — Municipal GDP and methodologyAbout 65 km in a straight line between the factory in Cabreúva, São Paulo, and the geographic center of the municipality (IBGE centroid). It is not a road route, freight cost or lead time.
Haversine formula, treating the Earth as a sphere with a radius of 6,371 km, between the factory’s reference coordinates (Av. Adolpho João Traldi, 80 - Jacaré, Cabreúva-SP) and the municipal centroid published by IBGE in its Geographic Mesh API, retrieved on September 24, 2026. The centroid is a reference point of the municipal territory, not the municipal seat or the delivery location. The result is rounded to multiples of 5 km; below 20 km, only “less than 20 km” is shown.
IBGE Mesh API documentationThe schedule for São Caetano do Sul should distinguish equipment availability, preparation for dispatch and transport. The proposal confirms dates and responsibilities for each stage according to the requested configuration.
Before dispatch to São Caetano do Sul, confirm the approved configuration, contracted documentation and delivery details with the sales team.
To review the FBE / FBEI families for the project in São Caetano do Sul, send the fluid and any known flow, pressure or head and temperature data. For replacement, add the installed pump’s identification and drawing. The team confirms the configuration and proposal scope.
Review process criteria and prepare the information for equipment selection.
FBE and FBEI selection for transferring CAP, bitumen, pitch and asphalt emulsions: product data, speed by viscosity, heating (chamber or jacket), start-up, materials and assembly documentation.
View applicationPump selection for B100 biodiesel production from vegetable oils and animal fats: reactor feed, methanol and catalyst, glycerin, washing, methanol recovery and storage — with material, sealing and motor criteria according to the project area classification.
View applicationFB Bombas technical guide to selecting liquid fuel transfer pumps — S10/S500 diesel, gasoline, ethanol, kerosene and jet fuel (JET-A1), heavy fuel oil and bunker — with the FBE (external gear) and FBCN (standardized centrifugal) series: viscosity, NPSH, overpressure protection, sealing and the installation standards (ABNT NBR IEC 60079, ABNT NBR 17505, NR-20 and NR-10), which are project requirements, not pump certifications.
View applicationJuice, mud, syrup, molasses, massecuite, must, wine, vinasse and ethanol: the data to measure at each point, the documented materials of the FBCN, FBE, FBEI and FBOT series and the NPSH, sealing and hazardous-area limits that decide the selection.
View applicationShare what you already know. Additional details can be clarified with the team during review.
What needs to be pumped, where it comes from and where it needs to go.
Flow, pressure or head, temperature and operating schedule, when known.
Series, model, identification and space or connection constraints, if a pump is already installed.
Project location, requested scope and documents required for your purchase.

FB Bombas is a Brazilian manufacturer with a history dating back to 1944. Our factory in Cabreúva, São Paulo, brings together CNC machining, assembly and a hydraulic test bench. The team reviews your application and confirms the configuration, documents and supply conditions in the proposal.
About FB BombasUse the family documentation and application guides to prepare your request.
Installation, operation and maintenance by series, with the document language identified.
Understand the process information needed to specify the equipment.
View applicationsSee the other pages for this city and for other cities. Service is provided by the factory in Cabreúva, Brazil.
Information to help you prepare your inquiry to FB Bombas.
The choice depends on the process stage. The catalogue for the FBE external gear pump lists paints, varnishes, solvents and resins, as well as lubrication systems and hydraulic equipment; the FBCN and FBME handle water and other clean or turbid liquids; and the FBOT serves thermal oil circuits. For the plant in São Caetano do Sul, state the stage, the fluid and the operating conditions; series and configuration are confirmed in the review.
It depends on the series, as set out in each manual: 10 kgf/cm² for the FBE (MTEC-01/01, Table 5), 1.5 times the operating pressure for the FBOT (MTEC-16/00), 1.5 times the working pressure for the FBME (MTEC-08/01) and per ANSI B73.1 for the FBCN (MTEC-03/00). The test is performed on the factory bench in Cabreúva, Brazil; certificates, additional tests and customer witnessing are defined in the proposal for supply to São Caetano do Sul.
The published grade is for the FBME: service manual MSERV-08/01 (item 12.2) specifies static and dynamic impeller balancing to grade G6.3. The manuals of the other series do not publish a grade; for them and for critical projects in São Caetano do Sul, specify the required standard, grade and report in the purchase scope. Impeller balancing alone does not guarantee the vibration level of the installation.
FB Bombas supplies the complete FBCN and checks, model by model, the dimensions in manual MTEC-03/00 (baseplate, nozzles, flanges and shaft) and the duty point before the order. The manual states mechanical construction per ASME B73.1; dimensional interchangeability with the existing pump is not assumed and is confirmed on the drawing. Send the identification and drawing of the pump installed in São Caetano do Sul, with flow, head, fluid, materials and drive.
The FBCN, a standardized centrifugal pump for clean or turbid liquids, with a series range of up to 2,200 m³/h and 135 m; when a higher head is required, the multistage FBME reaches 300 m. Each model has its own limits in the manual tables. For the project in São Caetano do Sul, state the fluid and the flow and head duty point; selection checks the model curve, suction conditions, materials, drive and installation interfaces.
Yes. The FBOT is the FB Bombas series developed for pumping organic thermal oils. Manual MTEC-16/00 states temperatures up to 350 °C within the series range and back pull-out construction, which allows the bearing-housing assembly to be removed without disconnecting the piping; the maximum discharge pressure varies with temperature (Figure 1 of the manual), and the fluid must not contain abrasive particles. For the circuit in São Caetano do Sul, send the oil identification and technical data sheet, the start-up and operating temperatures and the flow and head duty point; model, materials and sealing are confirmed for the circuit.
When the Data Book is part of the purchase scope. State which drawings, manuals, certificates and test reports are required for São Caetano do Sul; the proposal confirms the documents applicable to the supplied series and configuration. The same Data Book is not assumed for every pump.
It depends on the series. The FBE can have packing, a mechanical seal, a lip seal or a magnetic coupling; the standard seal is type 21, in ceramic, graphite and Viton, with an AISI 304 stainless-steel spring. The FBCN uses packing or a mechanical seal, the FBOT combines graphite packing as the first sealing stage with a mechanical seal immersed in the bearing-housing oil, and the FBEI accepts packing or a single, double or cartridge mechanical seal. State the fluid, concentration, temperature and pressure of the process in São Caetano do Sul to define the arrangement.
It depends on the series. The catalogue for the FBE external gear pump lists oils in general, greases, asphalt, diesel oil, kerosene, paints, varnishes, resins and solvents, as well as lubrication systems and hydraulic equipment. The FBEI internal gear pump is intended for high-viscosity liquids. The FBCN and FBME handle clean or turbid liquids, and the FBOT handles organic thermal oils free of abrasive particles and of substances that chemically attack the pump. For the process in São Caetano do Sul, state the composition, temperature, viscosity and solids content; fluids with suspended solids must be assessed by FB engineering.
It depends on the series. On the FBCN and FBOT, back pull-out construction allows the bearing-housing assembly to be removed without disconnecting the piping, and the FBEI catalogue also indicates back pull-out construction. The FBE external gear pump is not back pull-out: its shafts are supported on bushings. Before working on the equipment in São Caetano do Sul, check the series manual, the sectional drawing and the parts list.
Send your application to our factory team. You do not need every parameter defined to start the conversation.
The team reviews the information and confirms the details needed for a proposal. Configuration, availability, documentation, transport and lead time depend on the requested scope.
Describe the fluid, application and project destination. Include the model and technical data you already have.