I have a series or model
Review the equipment, dimensions and family documentation. For replacement, also provide the identification of your existing pump.
View the catalog
Direct service from our factory in Cabreúva, Brazil. Explore FB Bombas series and tell us what your operation needs to transfer or circulate.
Do you already know the pump or need help defining it? Choose the next step for your industrial project.
Review the equipment, dimensions and family documentation. For replacement, also provide the identification of your existing pump.
View the catalogTell us which fluid you need to transfer or circulate and how the pump will be used. You can start the conversation without all the technical details.
Describe my applicationSelection depends on the fluid and operating conditions. Location identifies the project and delivery destination.

External gear pumps for viscous fluid transfer. Check size-specific limits and availability with our sales team.
Explore models
Internal gear pumps for viscous fluid transfer. Review the configuration, materials and series documentation.
Explore modelsApplication context and points to confirm during technical and commercial review.
For projects in Cambé, Paraná, FB Bombas provides service from its factory in Cabreúva, Brazil. FBE external gear pumps and FBEI internal gear pumps have their own documentation and operating conditions. Provide the fluid, viscosity at operating temperature and any known flow and pressure data. The team reviews the appropriate configuration.
Identify the fluid by its trade name and available composition. Add viscosity at operating temperature, solids content and startup conditions. These data allow materials and sealing to be assessed before the configuration is confirmed.
For industrial projects in Cambé, FB Bombas provides direct service from its factory in Cabreúva, Brazil. A pump manufacturer since 1944, the company reviews the process, fluid and installation conditions with your team to define the equipment.
Delivery planning for Cambé needs the full address and plant access restrictions. Surrounding roads help locate the project, but the cargo route, carrier and timing must be confirmed when contracting transport.
State whether the requirement is an expansion, new installation or equipment replacement. For replacement, pump identification and its dimensional drawing help check the duty point and existing interfaces.
For gear pumps in Cambé, review FBE external gear pumps and FBEI internal gear pumps separately. Their models, drives and limits are not interchangeable; provide viscosity at startup and operating temperatures to assess the configuration.
The project location in Cambé does not determine the pump series. Compare families by fluid and process, then confirm selection using flow, pressure or head, temperature, viscosity and installation conditions.
For an industrial plant in Cambé, distinguish transfer, circulation, process feed and auxiliary services. Each circuit may need a different duty point and configuration, even within the same factory or industry.
If the project in Cambé requires testing or witnessed inspection, specify test points, acceptance criteria and required reports in the purchase requirements. The team confirms capability and scope before supply, according to the series and configuration.
For economic context, IBGE records GDP of R$ 6.8 billion for Cambé in 2023. In the 2021 gross value added breakdown, industry accounts for approximately 30.8% and agriculture for approximately 8.3%. Reference years differ because the 2022–2023 publication does not include a sector breakdown. These data describe the municipality; pumping requirements need to be specified for your plant’s process.
For fluids with varying properties in the process in Cambé, provide composition, temperature and viscosity ranges plus startup and cleaning conditions. Identify each product that will pass through the assembly to guide the review of materials, sealing and drive.
If the operation in Cambé uses different fluids, record composition, viscosity, temperature and solids content separately for each circuit. Compatibility with one product does not establish that the pump will serve every other plant process.
To describe the industrial application in Cambé, identify the process stage and whether the pump will transfer, circulate or feed another item of equipment. The same plant may have circuits with different fluid, flow, pressure and duty requirements.
Source: IBGE — Municipal GDP and methodologyAbout 430 km in a straight line between the factory in Cabreúva, São Paulo, and the geographic center of the municipality (IBGE centroid). It is not a road route, freight cost or lead time.
Haversine formula, treating the Earth as a sphere with a radius of 6,371 km, between the factory’s reference coordinates (Av. Adolpho João Traldi, 80 - Jacaré, Cabreúva-SP) and the municipal centroid published by IBGE in its Geographic Mesh API, retrieved on September 24, 2026. The centroid is a reference point of the municipal territory, not the municipal seat or the delivery location. The result is rounded to multiples of 5 km; below 20 km, only “less than 20 km” is shown.
IBGE Mesh API documentationThe schedule for Cambé should distinguish equipment availability, preparation for dispatch and transport. The proposal confirms dates and responsibilities for each stage according to the requested configuration.
Before dispatch to Cambé, confirm the approved configuration, contracted documentation and delivery details with the sales team.
To review the FBE / FBEI families for the project in Cambé, send the fluid and any known flow, pressure or head and temperature data. For replacement, add the installed pump’s identification and drawing. The team confirms the configuration and proposal scope.
Review process criteria and prepare the information for equipment selection.
FBE and FBEI selection for transferring CAP, bitumen, pitch and asphalt emulsions: product data, speed by viscosity, heating (chamber or jacket), start-up, materials and assembly documentation.
View applicationPump selection for B100 biodiesel production from vegetable oils and animal fats: reactor feed, methanol and catalyst, glycerin, washing, methanol recovery and storage — with material, sealing and motor criteria according to the project area classification.
View applicationFB Bombas technical guide to selecting liquid fuel transfer pumps — S10/S500 diesel, gasoline, ethanol, kerosene and jet fuel (JET-A1), heavy fuel oil and bunker — with the FBE (external gear) and FBCN (standardized centrifugal) series: viscosity, NPSH, overpressure protection, sealing and the installation standards (ABNT NBR IEC 60079, ABNT NBR 17505, NR-20 and NR-10), which are project requirements, not pump certifications.
View applicationJuice, mud, syrup, molasses, massecuite, must, wine, vinasse and ethanol: the data to measure at each point, the documented materials of the FBCN, FBE, FBEI and FBOT series and the NPSH, sealing and hazardous-area limits that decide the selection.
View applicationShare what you already know. Additional details can be clarified with the team during review.
What needs to be pumped, where it comes from and where it needs to go.
Flow, pressure or head, temperature and operating schedule, when known.
Series, model, identification and space or connection constraints, if a pump is already installed.
Project location, requested scope and documents required for your purchase.

FB Bombas is a Brazilian manufacturer with a history dating back to 1944. Our factory in Cabreúva, São Paulo, brings together CNC machining, assembly and a hydraulic test bench. The team reviews your application and confirms the configuration, documents and supply conditions in the proposal.
About FB BombasUse the family documentation and application guides to prepare your request.
Installation, operation and maintenance by series, with the document language identified.
Understand the process information needed to specify the equipment.
View applicationsSee the other pages for this city and for other cities. Service is provided by the factory in Cabreúva, Brazil.
Information to help you prepare your inquiry to FB Bombas.
Yes, in the five Custom Solutions categories: custom complete motor-pump assembly, mobile industrial kit, industrial pump skid, retrofit with a new FB pump in place of the installed one, and special materials projects. The scope of each project is defined with engineering before manufacture in Cabreúva, Brazil.
It depends on the series. The published limits are up to 260 °C for the FBCN, 350 °C for the FBOT, 340 °C for the FBEI and 140 °C for the FBME. For the FBE, the 2026 catalogue gives a range of 10 °C to 500 °C; the limit of each configuration depends on materials and sealing. These are series limits: they do not automatically apply to every model, nor do they necessarily occur together with the other maximums. State the start-up, operating and cleaning temperatures of the process in Cambé.
With the pump and part identification. State the pump model and identification, the part as shown in the parts list of the series manual, the urgency and the destination in Cambé; the team checks availability and confirms service and transport options. There is no published universal parts lead time or automatic guarantee of consignment stock. To reduce downtime, the FBEI (MAN001-10) and FBME (MSERV-08/01) manuals include the list of spare parts for two years of operation.
The catalogue includes FBE external gear, FBEI internal gear, FBCN standardized centrifugal, FBME multistage centrifugal and FBOT thermal oil pumps, fire systems and custom solutions. Review each family’s documentation; configuration and availability are confirmed in the quotation.
It depends on the model and the duty point; there is no single efficiency figure for the brand. The FBCN and FBME characteristic curves show the efficiency of each model and, for stainless-steel impellers with passages up to 15 mm, the FBCN manual deducts 2 or 3 points from the curve efficiency (Table 4). For the project in Cambé, compare the absorbed power at the process flow, head and fluid, also considering drive, control and operating duty.
By replacement, not refurbishment. FB Bombas replaces the old pump with a new, complete FB pump manufactured in Cabreúva, Brazil. Before the order, engineering assesses the installation and issues a data sheet and dimensional drawing; the drawing confirms whether the existing baseplate and piping can be kept or need adaptation. FB does not refurbish other manufacturers’ pumps, sell third-party parts or reuse the installed casing. For FB pumps in service, it supplies original parts and maintenance contracts.
Yes, when field service is part of the contracted scope. The services published by FB Bombas include start-up and commissioning and maintenance contracts for FB lines, and the FBME service manual recommends FB-authorized supervision during installation. For the project in Cambé, describe the service needed and the site; service format, schedule and commercial terms are defined in the proposal.
Send the application in Cambé, fluid, temperature and available flow, pressure or head data. For replacement, add the equipment model, identification and drawing. Also state the destination and purchase documentation requirements. The team confirms any additional data needed and the technical and commercial proposal scope.
Yes. The FBOT is the FB Bombas series developed for pumping organic thermal oils. Manual MTEC-16/00 states temperatures up to 350 °C within the series range and back pull-out construction, which allows the bearing-housing assembly to be removed without disconnecting the piping; the maximum discharge pressure varies with temperature (Figure 1 of the manual), and the fluid must not contain abrasive particles. For the circuit in Cambé, send the oil identification and technical data sheet, the start-up and operating temperatures and the flow and head duty point; model, materials and sealing are confirmed for the circuit.
No: manual MTEC-03/00 states mechanical construction per ASME B73.1, not dimensional compliance with that standard. So, before a replacement in Cambé, interchangeability with the existing pump is checked on each model’s drawing, together with the duty point, materials and drive.
Send your application to our factory team. You do not need every parameter defined to start the conversation.
The team reviews the information and confirms the details needed for a proposal. Configuration, availability, documentation, transport and lead time depend on the requested scope.
Describe the fluid, application and project destination. Include the model and technical data you already have.